Page 7
Telephone Line Monitor
The NX-6 has a Telephone Line Monitor that monitors the voltage and current of the telephone line for a detection of a
faulted phone line. This condition can also be reported to the central station. If the report is enabled, only the
Telephone Line Restore will be reported.
(Loc. 37, 39, and 40, pg. 19-20)
Temporal Siren Disable
NOTE: This feature must NOT be disabled for UL
installations.
If disabled, the Fire siren will be steady and Fire Voltage Out will be the same as Burglary (continuous). If enabled, the
Fire siren will be temporal.
(Loc. 37, pg. 19)
Tone Sniff Answering Machine Defeat
If enabled, only one call is required to defeat the answering machine. To use this feature you must have a Hayes 1200
Smart Modem. From the computer, call the panel as normal. When the answering machine answers, the panel will
hear the tones from the modem and seize the phone line for a download.
(Loc. 21, pg. 16)
Two Call Answering Machine Defeat
If enabled, to defeat an answering machine, two telephone calls must be made to the premises. On the first call, let the
phone ring one or two times. The control panel will detect these rings and start a 45-second timer, during which, the
control panel will answer the next call on the first ring.
This is not recommended for commercial applications.
(Loc. 21, pg. 16)
Walk-Test Mode
If enabled, entering [
r
] [Chime] followed by a user code will allow a walk-through zone test where all zones become
silent and local (non-reporting). Each time a zone is faulted, the zone light on the LED keypad will illuminate and the
chime will sound. The number of the faulted zone(s) will be displayed on the LCD keypad. It will also be entered into
alarm memory and the internal log. To exit at any time during this mode, enter a user code. Otherwise the
A
Walk-Test
Mode
@
will automatically exit after 15 minutes.
(Loc. 41, pg. 21)
Wireless Sensor Missing/Low Battery
The NX-6 will send a report to the central station when a wireless sensor has detected a low battery or has not reported
to the receiver. The "Service" LED will illuminate when either condition exists.
(Loc. 37, pg. 19)
Zone Bypassed Sounder Alert
If enabled, the NX-6 will beep the keypad sounder upon arming if a zone is bypassed.
(Loc. 23, pg. 17)
Zone Doubling
This feature allows you to use the six zones on the panel as twelve normally closed zones. When this feature is used,
zone seven cannot be a two-wire smoke zone, and European double E.O.L. configuration cannot be used.
THIS
FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 16 INCLUDING
WIRELESS.
Zones 7 - 12 should not programmed as
A
Fire
@
Zone Types when Zone Doubling is used. If one of the
twelve zones must be a fire zone, it must be one of Zones 1 to 6. The corresponding upper zone will become
unavailable. For example, if Zone 6 is a fire zone, then Zone 12 will not be available.
(Loc. 37, pg. 19)
Zone Types
The NX-6 has 20 programmable Zone Types that determine how each zone will function and report. The default Zone
Types are listed on page 18.
(Loc. 110-149, pg. 28)