Page 16
LOCATION 17
PARTITIONS REPORTED TO PHONE #3
1 segment, feature selection
Location 17 is used when events to be reported to a phone number are based upon the partition regardless of the event.
Program a
A
1" for Partition 1, and a
A
2" for Partition 2. If this location is used, location 16 should be "0".
LOCATION 18
CUSTOM COMMUNICATOR FORMAT
See locations 2, 8, & 14
Segment 1
â
On for 1800hz transmit; Off for 1900hz.
ã
On for 2300hz handshake; Off for 1400hz.
ä
On for cksum parity; Off for double round parity.
å
On for 2 digit event code; Off for 1 digit event code.
æ
Reserved.
ç
Reserved.
è
On for 20 p.p.s.; Off for 10 or 40 p.p.s.
é
On for 10 p.p.s.; Off for 20 or 40 p.p.s.
Segment 2
â
On for pager format (no handshake required).
ã
On for 1400/2300 handshake.
ä
Reserved
å
Reserved.
æ
On for Contact ID.
ç
On for SIA.
è
On for Contact ID or 4+3.
é
On for DTMF.
Segments 3 & 4
Reserved.
LOCATION 19
DOWNLOAD ACCESS CODE
8 segments, numerical data
Location 19 contains the eight-digit access code the NX-6 must receive from the downloading software before the panel
will permit downloading to occur. The factory default code is 84800000.
LOCATION 20
NUMBER OF RINGS TO ANSWER
1 segment, numerical data
Location 20 contains the number of rings to answer for a download. Enter a number from
A
0" (disabled) to "15". Factory
default is "8" and the NX-6 will answer on 8 rings.
LOCATION 21
DOWNLOAD CONTROL
1 segment, feature selection
Location 21 contains the feature selections for the controlling of download sessions. The following features can be
enabled or disabled using this location. (See the feature definitions beginning on page 3)
,
,
,
,
â
On enables two call answering machine defeat.
ã
On enables tone sniff answering machine defeat.
ä
On requires call back before download session.
å
Shutdown.
æ
On locks all local programming.
ç
On locks programming of all locations associated with the communicator.
è
On locks out download section.
(If "On", locations 19 - 22 cannot be viewed from the
keypad; can only be viewed from the keypad when "Off".)
é
On enables call back at auto test interval.
,
These can only be viewed from the keypad, must be changed through downloading.
LOCATION 22
DOWNLOAD CALL BACK NUMBER
20 segments, numerical data
If a telephone number is programmed into this location, and "Require Callback" is enabled in location 21, the control
panel will hang up for approximately 36 seconds (ensuring that the calling party has disconnected), and then call back.
If tone dialing is desired, program an "15" in the segment where tone dialing should begin. If the entire number should
be tone dialing, program an
A
15" in the first segment. Four-second delays can be obtained anywhere in the sequence by
programming a "13" in the appropriate delay location.
WARNING:
THE CALLBACK PHONE NUMBER SHOULD ALWAYS
BE REVIEWED FOR ACCURACY BEFORE DISCONNECTING.