Page 9
SET SYSTEM CLOCK
Step 1
Enter [
r
]-[
9
]-[
7
]-[
master code
]. The "Service" LED will flash.
Step 2
Enter
A
Hour Code
@
. This must be two digits, i.e. [hour 10's digit]-[hour 1's digit].
Step 3
Enter
A
Minutes Code
@
. This must be two digits, i.e. [minutes 10's digit]-[minutes 1's digit].
CHANGING USER CODES
Step 1
Enter [
r
]-[
5
]-[
master code
]. The "Ready" LED will flash.
Step 2
Enter the 2-digit user number (always 2 digits, i.e. "03" for user 3). The "Ready" LED will illuminate
steady.
Step 3
Enter the new user code designated for that individual. The "Ready" LED will flash indicating that the
code was accepted. If it rejects the code, the sounder will beep 3 times.
Step 4
If another user code needs to be programmed, return to step 2.
Step 5
Press [
#
] while the "Ready" LED is flashing to exit the User Code Programming Mode.
ASSIGNING AUTHORITY LEVEL
Step 1
Enter [
r
]-[
6
]-[
master code
]. The "Ready" LED will flash.
Step 2
Enter [2 digit user number] (always 2 digit such as 03 for user 3). The "Ready" LED will illuminate
steady and the "Instant" LED will flash. Refer to the chart below for the description of each LED. Turn the
LED on for the features that you desire
.
LED
ATTRIBUTES IF LED 8 IS OFF
LED
ATTRIBUTES IF LED 8 IS ON
1
Reserved
1
Activate output #1
2
Arm Only
2
Activate output # 2
3
Arm Only After Close Window
3
Activate output # 3
4
Master arm/disarm (can program other codes)
4
Reserved
5
Arm/disarm code
5
Arm/disarm
6
Allowed to bypass zones (see location 23)
6
Bypass Zones
7
Code will send open / close reports
7
Open / Close Reporting
8
If this LED is on, LEDs 1-7 will use the chart to the right
8
If this LED is off, LEDs 1-7 use the chart to the left
Step 3
Enter [
r
]. The "Instant" LED will illuminate steady. This moves you to the partition enable, which tells
the system what partition this user can arm/disarm.
Step 4
LEDs 1-2 illuminate for each partition that the user has authorization for. To change any of these
numbers, press 1-2 to permit or deny access to the user.
Example: If LED #2 is lit, then user has
assigned access to that partition. By pressing the [
2
] key, the LED will go off indicating the user has
been denied access to that partition.
)
Step 5
Enter [
r
]. This returns you back to step 2 above. At this point you may enter another user number to
assign attributes for. Continue this procedure until you have assigned authority levels to all users.
Step 6
Press [
#
] key to exit the Assigning Authority Level Program.
NOTE: Any master arm/disarm code can add or change a user code if the master code has access to the
same partitions as the code being added/changed. Consequently, when programming the user codes for a
partitioned system
,
leave at least one code
(can be "Go to Program code" if enabled in location 43) with
access to all partitions or you will not be able to add new users. If you desire the end user to be able to add
new codes, you must remove the partition authority from all blank codes.
[
r
]-[9]-[8]
Pressing
[
r
]-[
9
]-[
8
] while the system is disarmed will cause the control to do a callback for a download.
NOTE: A valid user code may be required after [
r
]-[9]-[8] if enabled in loc. 41.
[
r
]-[9]-[9]
Pressing
[
r
]-[
9
]-[
9
] while the system is disarmed will cause the control panel to seize the phone line for
a download.
NOTE: A valid user code may be required after [
r
]-[9]-[9] if enabled in loc. 41.