![GE NetworX NX-6 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019047.webp)
ANSI
/ S
IA CP
-0
1 R
EQUIRE
M
ENTS
To
m
e
e
t
SI
A C
P
-0
1 re
quir
e
m
ent
s –
•
Minim
u
m Sy
stem Requir
ements: 1 c
o
ntrol pa
nel; 2 keypads (
o
r 1 keypad per partition
for mult
i-partitio
ned sys
tems)
•
Remote armi
ng shall
NOT
be enabled in SI
A classif
ied install
a
ti
ons.
•
Off-pr
e
mise transmissio
n
m
u
st be in
the SI
A for
m
at.
•
The Abort
wi
ndow and
En
try Delay m
u
st not excee
d 1 mi
nute.
•
CAUTIO
N –
A cal
l wai
ti
n
g
cancel on
a non-ca
ll w
a
iti
n
g line
w
ill prevent s
u
ccessful connectio
n
to
th
e centra
l st
ation.
CP-01 F
eat
ure
Descri
p
tion
Featur
e De
scri
p
tion
as
sho
w
n in manua
l
Program
Loc
Seg / Opt
Factor
y
Default
CP-01 R
e
quir
e
d
Setting
Exit Time
Exit 1 De
lay
24
2
60
45 –
24
0 sec.
Exit 2 De
lay
24
4
60
45 –
24
0 sec.
Progress A
n
n
uncation / Dis
a
ble
– f
o
r Silent
Exit
Silent Keypad
Option
9
3
2
All annunciators enabled
Allowed
(individual keypads may be disabled)
Exit Time Restart
This feature is non-programmable in the
panel.
Enabled
Auto Stay Arm on Unvacated
Premises
Auto Bypass
23
1
/
3
Enabled Enabled
Exit Time and
Progress
Annu
nciation / Disable
– for
Remote
Arm
This feature is non-programmable in the
panel. --
Exit t
ime and pr
ogress are always
enabled.
Enabled (may be disabled
f
o
r remote ar
ming)
Entry Delay(s
)
Entry 1 Delay
24
1
30
30 –
24
0 sec.
Entry 2 Delay
24
3
30
30 –
24
0 sec.
Abort Window
– for
Non-Fire Zones
Dialer De
lay
40
8
30 Enabled
(may be disabled by zone/ z
o
ne
type)
Abort Window Time
– for
Non-Fire Zones
Dialer De
lay
40
8
30
15 –
45
sec.
NOTE
:
Combined
Abort
window and
Ent
ry D
e
lay
must
not
exc
eed 1
minut
e.
Abort Annun
ciation
This feature is non-programmable in the
panel. --
Fla
s
hing Canc
el LED goes off
when
disarming.
Enabled
Cancel An
nun
ciation
Cancel
23
3
/
6
Enabled Enabled
Duress Featur
e
Duress
44
Disabled
Disabled
Cross Zoning
2 T
rips
on
Cros
s
Zone
37
5
/
4
Disabled
Required
Keypad sounds on Cross Zone trip
39
5
Disabled
Z
o
ne
T
y
pe
Cha
ra
c
te
ri
st
ic
111
3
/
4
Disabled
Programmable Cross Zoning Time
Cros
s
Zone
T
im
e
40
6
5 minutes
Allowed
Swinger S
hutdown
Swinger S
hutdown Count
38
n/a
Enabled for
1
trip
For all
non-fir
e
zones, shut
down at 1
–2
tr
ips
Swinger S
hutdown Disable
Swinger S
hutdown Count
38
n/a
Enabled
for 1 trip
Allowed
Fire Alarm Verificati
on
Fire Alarm Verificati
on Time
40
9
Disabled
Required (depends on panel & sensor
s)
Call Waiting
Cancel
Must be progr
ammed as part o
f
the phone number
0
n/a
n/a
Required (depends on user
phone line)
Default Chang
e
s (from prior
versions)
:
Recent Closin
g
23
3 / 7
Enabled
Exit
Error
23
3 / 8
Enabled
Power Up Del
ay
40
3
60 sec.
IMPORTA
NT
NOTE
:
UL requireme
nts
take pri
o
rity o
v
er
SIA require
m
ents.
Содержание NetworX NX-6
Страница 1: ...NetworX Series NX 6 CONTROL PANEL Installation and Startup ...
Страница 42: ...Page 40 NX 6 WIRING DIAGRAM ...