![GE NetworX NX-6 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019010.webp)
Page 8
PROGRAMMING THE LED KEYPADS
This section describes how to program the address and partition of each keypad as well as the options that are available.
The address of the keypad is important because this is how the panel supervises the keypads. The factory default for the
Master code is [
1
]-[
2
]-[
3
]-[
4
] when using a 4-digit code or [
1
]-[
2
]-[
3
]-[
4
]-[
5
]-[
6
] for a 6-digit code. The factory
default for the "Go To Program" code is [
9
]-[
7
]-[
1
]-[
3
] for a 4-digit code or [
9
]-[
7
]-[
1
]-[
3
]-[
0
]-[
0
] for a 6-digit code.
SET STARTING ZONE
(Refer to feature definitions)
Step 1
Enter [
r
]-[
9
]-[
2
] [
program code
]. The "Service" LED will illuminate steady.
Step 2
Enter the starting zone for this keypad (
1-16
) followed by [
r
].
SET KEYPAD OPTIONS
Step 1
Enter [
r
]-[
9
]-[
3
] [
program code
]. The "Service" LED will flash.
Step 2
LEDs 1-8 can now be toggled on/off to enable/disable the functions in the following chart.
Step 3
After enabling/disabling the desired functions press [
r
].
LED
KEYPAD FEATURE ENABLED
1
Reserved.
DO NOT PROGRAM THIS AT ALL!
2
Enable Silent Keypad option
. Silences the entry/exit sounder & chime only.
3
Enable
A
Ding Dong
@
sound for chime -
If off, chime will be a single tone. (Loc. 40)
4
Enable Keypress Silence option
- silences the pulsing keypad sounder for 5 seconds when a key is pressed.
5
Enable Armed Status Suppression
- will not allow the keypad to display faulted or bypassed zones when the system is
armed.
6
Enable Panic, Fire, Medical Beeptone
- will sound a short beep to verify that the keypress was accepted.
7
Suppresses the "Service" LED
- will not allow the "Service" LED to illuminate for any reason. If there is a system trouble,
pressing [
r
]-[
2
] will still show the Service menu. (
NOTE: For UL installations, the Service LED shall not be
suppressed
.)
8
Enable multi-partition viewing
- enables temporary viewing of all partitions by pressing [
r
]-[
1
]-[partition number].
SET KEYPAD NUMBER AND PARTITION
Step 1
Enter [
r
]-[
9
]-[
4
]-[
program code
]. The "Service" LED and the "Instant" LED will flash.
Step 2
Enter the keypad number (1-8).
Step 3
Press [
r
]. The "Instant" LED will illuminate steady and the "Service" LED will remain flashing.
Step 4
Enter the partition number for the keypad. The keypad will automatically exit this mode now.
SET ELAPSED INCREMENTS SINCE LAST AUTOTEST
Step 1
Enter [
r
]-[
9
]-[
5
]-[
program code
]. The "Service" LED will flash.
Step 2
Enter [100's digit] -[10's digit]-[1's digit]-[#]
SET SYSTEM DATE
Step 1
Enter [
r
]-[
9
]-[
6
]-[
master code
]. The "Service" LED will flash.
Enter
A
Day of Week
@
Step 2
1 = Sunday
5 = Thursday
2 = Monday
6 = Friday
3 = Tuesday
7 = Saturday
4 = Wednesday
Enter
A
Month Code
@
. This must be two digits, i.e. [month 10's digit]-[month 1's digit].
Step 3
01 = January
05 = May
09 = September
02 = February
06 = June
10 = October
03 = March
07 = July
11 = November
04 = April
08 = August
12 = December
Step 4
Enter
A
Day Code
@
. This must be two digits, i.e. [day 10's digit]- [day 1's digit].
Step 5
Enter
A
Year Code
@
. This must be two digits, i.e. [year 10's digit]-[year 1's digit].