![GE NetworX NX-6 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019037.webp)
Page 35
LOC PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
CUSTOMIZING ZONE TYPES (GROUPS)
110
28 ZONE TYPE 1 ALARM EVENT CODE
8
__
ZONE TYPE 1 CHARACTERISTIC SELECTION
Segment #1
1 - Fire (enable for fire zone)
“
2 - 24 Hour (enable for non-fire 24 hour zone)
“
3 - Keyswitch zone
“
4 - Follower (enable for burg zones that are instant during non-entry times)
“
5 - Delay 1 zone (enable to follow Timer #1 Entry/Exit)
“
6 - Delay 2 zone (enable to follow Timer #2 Entry/Exit)
“
7 - Interior (Enable for auto bypass or stay arming)
“
8 - Local Only (enable if zone is not to be reported)
“
Segment #2
1 - Keypad audible on alarm
“
2 - Yelping siren on alarm
“
3 - Temporal siren on alarm
“
4 - Chime
“
5 - Bypassable
“
6 - Group Shunt
“
7 - Force armable
“
8 - Entry Guard
“
111
28
Segment #3
1 - Reserved
2 - Double End of Line Tamper zone
“
3 - Trouble zone (Day zone)
“
4 - Cross Zone
“
5 - Dialer Delay zone
“
6 - Swinger zone
“
7 - Restore reporting
“
8 - Listen-In
“
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF EACH OF
THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM TABLE 3.1, PAGE 28 TO UNDERSTAND THESE DEFAULTS.
112
28 ZONE TYPE 2 ALARM EVENT CODE
2
____
113
28
ZONE TYPE 2 CHARACTERISTIC SELECT
2-125-78
_____ _____ _____
114
28
ZONE TYPE 3 ALARM EVENT CODE
7
____
115
28
ZONE TYPE 3 CHARACTERISTIC SELECT
5-1245-5678
_____ _____ _____
116
28
ZONE TYPE 4 ALARM EVENT CODE
5
____
117
28
ZONE TYPE 4 CHARACTERISTIC SELECT
45-125-5678
_____ _____ _____
118
28
ZONE TYPE 5 ALARM EVENT CODE
5
____
119
28
ZONE TYPE 5 CHARACTERISTIC SELECT
457-125-5678
_____ _____ _____
120
28
ZONE TYPE 6 ALARM EVENT CODE
4
____
121
28
ZONE TYPE 6 CHARACTERISTIC SELECT
0-1245-5678
_____ _____ _____
122
28
ZONE TYPE 7 ALARM EVENT CODE
0
____
123
28
ZONE TYPE 7 CHARACTERISTIC SELECT
2-0-78
_____ _____ _____
124
28
ZONE TYPE 8 ALARM EVENT CODE
1
____
125
28
ZONE TYPE 8 CHARACTERISTIC SELECT
1-13-378
_____ _____ _____
126
28
ZONE TYPE 9 ALARM EVENT CODE
7
____
127
28
ZONE TYPE 9 CHARACTERISTIC SELECT
6-1245-5678
_____ _____ _____
128
28
ZONE TYPE 10 ALARM EVENT CODE
2
____
129
28
ZONE TYPE 10 CHARACTERISTIC SELECT
24-5-78
_____ _____ _____
130
28
ZONE TYPE 11 ALARM EVENT CODE
3
____
131
28
ZONE TYPE 11 CHARACTERISTIC SELECT
3-0-0
_____ _____ _____
132
28
ZONE TYPE 12 ALARM EVENT CODE
5
____
Содержание NetworX NX-6
Страница 1: ...NetworX Series NX 6 CONTROL PANEL Installation and Startup ...