MDS 05-3438A01, Rev. F
MDS 4790/9790 Series I/O Guide
57
The table below gives the text message displayed by the
STAT
command for each alarm event.
Unit’s Internal
Temperature
TEMP
This command displays the radio’s internal temperature in degrees Cel-
sius. Note that the radio is designed to operate in a range from –30 C° to
+60 C°, and may fail at temperatures outside this range. This internal
reading might be higher than the outside temperature by several degrees.
Clock Formatting
TIME [hh:mm:ss]
This command sets or displays the time in 24-hour format. The accuracy
of the date and time are important because events are logged with the
date and time (see
“DATE [mmm dd yyyy]” on Page 44
).
Table 13. Text Messages of Alarm Event Codes
Event
Number
Text Message
01
Hardware mismatch
02
Model number not programmed
03
Authorization fault
04
Synthesizer out-of-lock
06
A/D fault
07
Voltage regulator fault detected
08
Radio not calibrated
10
EEPROM write failure
12
Receiver timeout
13
Transmitter timeout
15
Output power fault
16
Unit address not programmed
17
Data parity error
18
Data framing error
20
Configuration error
25
10V regulator output not in valid
range
26
DC input power is not in valid range
27
LNA current is not in valid range
28
Board current not in valid range
31
Internal temperature not in valid
range
Show Temperature and
Voltages screen
,
Page 78
A
B
Set Time screen
,
Page 77
A
B