NOTE:
Changing the transmitter’s operating frequency may result in degraded or
out-of-specification performance. Review
Section 8.4,
Operating
Frequency Change Considerations, beginning on Page 89
before making a
change.
Receive
Frequency
Use this screen to set or show the receive frequency.
Normally, the radio ships programmed with the customer-specified frequency. If
you did not specify the operating frequency when the radio was ordered, the factory
sets the RX frequency to the center of the radio’s operating band. The range of
frequencies for standard models are provided in
Section 10.1,
Technical
Specifications, beginning on Page 97
.
To change the current frequency, press ENTER, then press the left/right arrow
buttons to select a digit. Use the up/down arrow buttons to increase or decrease
the number. Press ENTER to make the change.
NOTE:
Changing the receiver’s operating frequency may result in degraded or
out-of-specification performance. Review
Section 8.4,
Operating
Frequency Change Considerations, beginning on Page 89
before making a
change.
Output Power
Setting [37-20]
Use this screen to set or show the transmit power output setting. Set power output
from +37 dBm to +20 dBm.
To change this value, press ENTER, then use the left/right arrow buttons to select
a digit. Use the up/down arrow buttons to increase or decrease the number. Refer
to
Table 18
to convert dBm to watts if necessary. Press ENTER to make the
change.
Modem
Use this screen to set or show the internal modem speed for compatibility with the
modem in the central host computer.
To change the modem speed, press ENTER, then use the up/down arrow buttons
to show available modem speeds. Press ENTER to make the change.
Review the Receive Level parameter on
Page 75
and the Transmit Gain parameter
on
Page 75
for guidance on setting appropriate levels.
R e c e i v e F r e q u e n c y
4 0 0 . 0 0 0 0 0 M H z
RX [xxx] command
,
Page 52
O u t p u t P o w e r S e t t i n g
3 0 d B m
Table 18. dBm Vs. Watts
dBm
Watts
dBm
Watts
+37 dBm
5.0 watts
+27 dBm
500 milliwatts
+35 dBm
3.2 watts
+25 dBm
320 milliwatts
+33 dBm
2.0 watts
+23 dBm
200 milliwatts
+31 dBm
1.25 watts
+20 dBm
100 milliwatts
+29 dBm
800 milliwatts
PWR [20–37] command
,
Page 51
M o d e m
4 8 0 0
MODEM
[NONE/4800/9600/19200/
DEFAULT] command
,