MDS 05-3438A01, Rev. F
MDS 4790/9790 Series I/O Guide
85
4. Use the
DLINK ON
and
DLINK [baud rate]
commands to
enable network-wide diagnostics and set the baud rate at the
DIAG-
NOSTICS
port of each node radio.
5. Connect same-site radios using a null-modem cable at the radios’
DIAGNOSTICS
ports.
6. Connect a PC on which MDS InSite software is installed to the root
radio, or to one of the nodes, at the radio’s
DIAGNOSTICS
port (this
PC can be the PC that collects payload data, as shown in
Figure 37
).
To connect a PC to the radio’s
DIAGNOSTICS
port, an RJ-11 to
DB-9 adapter (MDS P/N 03-3246A01) is required. If desired, you
can construct an adapter cable from scratch using the information
shown in
Figure 38 on Page 86
.
7. Launch the MDS InSite software at the PC. See the
InSite Radio
System Management Software User’s Guide
for instructions.
Invisible place holder
Figure 37. Network-Wide Remote Diagnostics Setup
R TU
R TU
TO
DIAGNOSTICS
PORT
TO DATA
PORT
MASTER STATION
ROOT
DTYPE
ROOT
DIAGNOSTICS DATA
(TO InSite)
HOST COMPUTER
PAYLOAD DATA
R TU
(TO SCADA APPLICATION)
DTYPE
NODE
DTYPE
NODE
DTYPE
NODE