26
49-2000492 Rev. 0
Installation Instructions
C. OUTSIDE BACK EXHAUST
(Horizontal Duct) (Cont.)
C3
USE TOP CABINET TEMPLATE
FOR PREPARATION OF TOP
CABINET
You need to drill holes for the top support screws
and a hole large enough for the power cord to fit
through.
• Read the instructions on the TOP CABINET
TEMPLATE.
• Tape it underneath the top cabinet.
• Drill the holes, following the instructions on the TOP
CABINET TEMPLATE.
CAUTION
Wear safety goggles when
drilling holes in the cabinet bottom.
C4
ADJUST BLOWER EXHAUST
The unit is shipped in the top exhaust configuration.
To adjust the unit to back exhaust remove damper
mounting plate and reposition such that opening is
in the back of the unit.
CAUTION
Wear gloves to protect against
sharp edges.
1. Remove 3 screws as shown and save.
2. Remove damper mounting plate by removing
screws.
3. Reposition damper mounting plate such that
opening is in the back of the unit.
4. Reattach screws.
C5
ASSEMBLE AND INSTALL
ADAPTER
1. Remove the tape from the damper.
Make sure
that the damper pivots easily before mounting
the unit
.
You will need to make adjustments to assure
proper alignment with your house exhaust duct
after the unit is installed.
2. Position the unit damper to back of the unit and
secure it with the screws that were removed.
NOTE:
Damper must hinge at the top as shown
below.
INSTALLATION INSTRUCTIONS