B-2
15" QuickPanel* View & QuickPanel Control Loaded Color TFT
– December 2011
GFK-2402D
B
Physical Unit
Problem
Suggested Remedy
Slow or sluggish touch
response.
Ensure that configured I/O or communications
channels such as serial or Ethernet are operating
without error. These errors can cause higher system
overhead leading to delayed response to touch
inputs.
Ensure that flash drives, internal or external, are
operating without error. If the flash drives are highly
fragmented or corrupted, reads and writes to the
drive can experience significant delays leading to
delayed response to touch inputs. Corrupted
external flash drives may be corrected with Storage
Manager. See “Storage Manager” in chapter 3.
Problem
Suggested Remedy
After adding expansion memory
in the DIMM connector, the
system won’t boot, or if it does
boot, an error message is
displayed.
When the system is first started, observe the screen
to notice any memory error messages from the boot
loader. If any mess
ages appear, such as “DIMM not
12 row”, “DIMM not 32 bit”, “DIMM refresh
unsupported”, power down the system and remove
the memory module. If the error message is
displayed from the Windows CE desktop, also
power down the system and remove the memory
module. For proper operation, expansion memory
modules must meet the requirements stated in the
Design Specifications.