background image

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

   

  

 

 

GFL-002 

Warnings, Cautions, and Notes 

as Used in this Publication 

Warning 

Warning notices are used in this publication to emphasize that hazardous voltages, 
currents, temperatures, or other conditions that could cause personal injury exist in this 
equipment or may be associated with its use. 

In situations where inattention could cause either personal injury or damage to 
equipment, a Warning notice is used. 

 

Caution 

Caution notices are used where equipment might be damaged if care is not taken. 

 

Note:

  Notes merely call attention to information that is especially significant to 

understanding and operating the equipment. 

This document is based on information available at the time of its publication.  While efforts 
have been made to be accurate, the information contained herein does not purport to cover 
all details or variations in hardware or software, nor to provide for every possible contingency 
in connection with installation, operation, or maintenance.  Features may be described herein 
which are not present in all hardware and software systems.  GE Intelligent Platforms 
assumes no obligation of notice to holders of this document with respect to changes 
subsequently made. 

GE Intelligent Platforms makes no representation or warranty, expressed, implied, or statutory 
with respect to, and assumes no responsibility for the accuracy, completeness, sufficiency, or 
usefulness of the information contained herein.  No warranties of merchantability or fitness 
for purpose shall apply. 

 

 

 

 

*  indicates a trademark of GE Intelligent Platforms, Inc. and/or its affiliates.  All other 

trademarks are the property of their respective owners. 

 

©Copyright 2005 – 2011 GE Intelligent Platforms, Inc. 

All Rights Reserved 

Содержание IC754CSF15CTD

Страница 1: ...l View QuickPanel Control Loaded Color TFT IC754CSF15CTD IC754CBF15CTD IC754CGF15CTD IC754VBF15CTDEX IC754VGF15CTDEX IC754VSF15CTDEX IC754VSF15CTD IC754VBF15CTD IC754VGF15CTD IC754CBF15CTDEX IC754CGF15CTDEX IC754CSF15CTDEX Hardware User sGuide GFK 2402D December 2011 ...

Страница 2: ...the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Intelligent Platforms assumes no obligation of notice to holders of this document with respec...

Страница 3: ...available Technical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support www ge ip com support Phone 800 1 433 2682 EMEA Direct Dial 352 26 722 780 if toll free 800 option is unavailable or if dialing from a mobile telephone Technical Support Email support emea ip ge com Customer Ca...

Страница 4: ......

Страница 5: ...or more video patent portfolio licenses such as and without limitation VC 1 and MPEG4 Part 2 Visual for the personal and non commercial use of a consumer to i Encode video in compliance with the standards licensed under such patent portfolio licenses and or ii Decode video that was encoded by a consumer engaged in a personal and non commercial activity and or was obtained from a video provider lic...

Страница 6: ...SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 10 b of the National Electric Code NFPA 70 and or in accordance with the authority having jurisdiction Users must supply an isolated DC supply to power the QuickPanel models covered by this manual The power supply to the QuickPanel must be...

Страница 7: ... Installation Using Mounting Clamps 3 4 Connecting a DC Power Supply 3 5 Field Replaceable Components 3 6 Detailed Operation 4 1 Touch Screen Display 4 2 Communication Ports 4 11 CF Port 4 23 Universal Serial Bus USB 4 24 Ethernet 4 25 Printing 4 32 Expansion Bus 4 35 DIP Switches 4 36 Memory 4 38 Other Subsystems 4 43 Design Specifications A 1 Physical A 1 DC Power A 1 Display A 2 Front Panel A 2...

Страница 8: ...ickPanel View QuickPanel Control Loaded Color TFT December 2011 GFK 2402D Environmental A 5 Battery A 5 Calendar Clock A 5 Agency Approvals A 6 Diagnostics B 1 Power up B 1 Pocket Internet Explorer B 1 Physical Unit B 2 ...

Страница 9: ... learning curve for operators and developers alike The availability of third party application software makes this operating system even more attractive The 15 QuickPanel View and QuickPanel Control are all in one microcomputers designed for maximum flexibility The design based on an advanced XScale microprocessor brings together a high resolution touch screen operator interface with a variety of ...

Страница 10: ...upplied quick connect plug Refer to the procedures in Connecting a Power Supply in chapter 3 Depending on your application you may also want to connect and configure optional input devices communications ports and expansion adapters see chapter 3 Caution Electrical Shock Hazard To avoid personal injury or damage to equipment ensure that the DC supply is disconnected from power and that the leads a...

Страница 11: ...tart the QuickPanel View Control 1 Apply DC power to the QuickPanel View Control Once power is applied the QuickPanel View Control begins initializing The first thing to appear on the display is the splash screen 2 To skip running any programs included in the StartUp folder tap Don t run StartUp programs The splash screen disappears automatically after about 5 seconds The Windows CE desktop then b...

Страница 12: ...ou perform the following procedure To shut down the QuickPanel View Control 1 Quit any programs that are running and wait for all file operations to complete 2 If you have not changed operating system settings e g brightness or touch screen sensitivity or do not want to save the changes remove AC power from the DC supply 3 To save changes to operating system settings e g brightness touch screen se...

Страница 13: ...wing user accessible controls and indicators and a block diagram showing module functions QuickPanel View Control Software 2 5 Working with Windows CE working with Pocket Internet Explorer backing up registry or desktop changes rebooting the system using Storage Manager and System Information utilities using Microsoft file viewers copying projects to the Flash Card updating a Machine Edition proje...

Страница 14: ...attery The following diagram shows the physical layout of the QuickPanel View Control and the locations of ports and connections Caution Remove power from the QuickPanel View Control before opening the back Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow...

Страница 15: ...GFK 2402D Chapter 2 Overview 2 3 2 and battery Physical Layout of QuickPanel View Control ...

Страница 16: ...e 15 QuickPanel View QuickPanel Control are based on the XScale PXA255 microprocessor and employs large scale integration to provide high performance with a small footprint The following block diagram illustrates the major functional areas of the QuickPanel View Control and the interfaces between them ...

Страница 17: ...tens the learning curve for users having experience with Windows 95 98 NT 2000 ME XP From a software developer s perspective the CE environment is a subset of the WIN32 application programming interface simplifying the porting of existing software from other versions of Windows The QuickPanel View Control operating system is stored in a 16 MB block of FLASH memory and copied to a block of DRAM for...

Страница 18: ... the touch screen calibration SPACEBAR Equivalent to single tap ENTER Equivalent to double tap In a dialog box equivalent to OK TAB In a dialog box select next control SHIFT TAB In a dialog box select previous control CTRL TAB In a tabbed dialog box open the next tab ESC Close dialog box discarding changes ARROW KEYS In a dialog box select controls or items from a list box To place a program in th...

Страница 19: ...Explorer does not support VBScript however VBScript components are included in the operating system and may be used by third party applications such as Proficy Machine Edition A connection can be established over a dial up connection default or an Ethernet network The Ethernet or dial up connection must first be properly configured To configure a dial up connection 1 Start Pocket Internet Explorer...

Страница 20: ...r 2011 GFK 2402D 2 To configure a LAN Connection 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears 3 On the Connection tab select the Use LAN check box 4 Tap OK 5 To save the settings run Backup see page 2 10 ...

Страница 21: ...ction tab select the Access the Internet using a proxy server check box 4 In the Address box type the URL of your proxy server see your ISP or network administrator 5 In the Port box type the server s port number for HTTP access 6 Select the Bypass Proxy for Local Addresses check box to connect directly to sites like your intranet 7 Tap OK 8 To save the settings run Backup see page 2 10 ...

Страница 22: ...kup does the following It stores the Windows CE registry including any control panel settings in Flash memory It stores any changes or additions made to the Windows subtree of the file system in the user block of FLASH memory Run Backup whenever you make configuration changes to the operating system or installed applications and prior to shutting down the QuickPanel View Control To run the Backup ...

Страница 23: ...ystem then restarts the QuickPanel View Control This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 2 10 2 Tap Start point to Programs then the System folder and tap Reboot A confirmation dialog box appears 3 Tap Yes The operating system reboots ...

Страница 24: ... volumes Storage Manager can repair data volumes existing either in Compact Flash CF battery backed SRAM BBSRAM or USB Flash Keys thumb drives Data volumes existing in the main flash file system of the QuickPanel may not be repaired by Storage Manager Storage Manager accessed from the Control Panels folder is a Microsoft product for which on line help is available ...

Страница 25: ...em Information window which provides information such as hardware version and serial number CPU type and specifications etc This information can be especially useful if you are contacting Technical Support To run the System Information program 1 On the desktop double tap System Information The System Information splash screen appears 2 Tap More Info to open the Advanced System Information window o...

Страница 26: ...e Viewer Limitations Microsoft Excel Hyperlinks are not supported Data Tables in charts are not supported WordArt is not supported Plain text will be substituted Surface charts An image representing an unsupported chart will appear in the chart s location Certain types of 3D charts will be mapped to equivalent 2D charts Supported 3D charts are only shown at a fixed camera angle Vertical text in th...

Страница 27: ...shown in 90 degree increments Type 1 fonts are mapped using either the encoding or Unicode mappings if possible Type 3 fonts are not supported but an attempt is made to map them if a Unicode map exists Copy Project to Flash Card RestorePCCard is a custom utility for transferring ProficyTM Machine Edition Projects between compatible QuickPanel View Control units via CF cards Caution Ensure that the...

Страница 28: ... Control automatically loads the new project from the CF Card overwriting the old project on the machine 3 Remove the CF Card from the slot Emulate PPC Emulate PPC is a utility that allows the QuickPanel to emulate a Pocket PC 2003 during an ActiveSync session enabling the download of third party Pocket PC 2003 software To use Emulate PPC during an ActiveSync session 1 Start Windows Explorer doubl...

Страница 29: ...ecutable EXE file included in the 15 QuickPanel View QuickPanel Control s operating system The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to function the HTTP File Transfer utility requires both computers to have web servers that support PUT functionality Most web servers support PUT including the Proficy Machine Edition web server installed with the r...

Страница 30: ...rver webfiles MyFileBACKUP txt Copies a file called MyFile txt on drive C of the local computer to the webfiles folder under the web server at MyServer Note that you can rename a file as you copy it HTTPUTIL DELETE url Where url is the remote URL of the file you want to delete This URL must use the or HTTP syntax For example HTTPUTIL DELETE http MyServer webfiles MyFileBACKUP txt Deletes a file ca...

Страница 31: ...S which uses different ports and is based on SSH rather than SSL All configuration of the FTP server is accomplished with the Secure FTP Server control panel applet By default the server is not enabled Once enabled a background program will run waiting for clients to connect Up to ten connections are supported Sessions that are idle for five minutes are terminated by the server Note To save the se...

Страница 32: ...and Required are enabled By default the server requires a username password combination to be configured The server supports one username password combination to authenticate remote users There are three modes of authentication operation No support for anonymous login This is the default Anonymous with no password This is enabled when Allow Anonymous Access is checked but Require Username and Pass...

Страница 33: ...removed and inserted it will still work provided the CF card s device name did not change during reinsertion A server certificate is a special type of document that contains information about the server s settings and a chain of electronic signatures to guarantee the document has not been altered A Server certificate must be chosen from the certificates available in the QuickPanel View Control Sec...

Страница 34: ... signed certificate 1 Open a command prompt window by selecting the Start menu selecting Programs then Command Prompt 2 From the command prompt type genslfcert CN unique identifier You may specify a unique identifier of your choice such as machine name machine location or IP address in place of unique identifier 3 A self signed certificate is created in the My Certificates section of the certifica...

Страница 35: ...n appears 4 Specify whether Windows should place the certificate in a certificate store or select another location Click Next to continue The Completing the Certificate Import Wizard screen appears 5 Click Finish to complete the installation of the certificate The Security Warning message appears This message informs you Windows will automatically trust any certificate issued by this Certification...

Страница 36: ......

Страница 37: ...exceeding 40 of the rated voltage In Class I Zone 2 hazardous areas the product shall be mounted using supplied mounting clamps to the flat surface of an enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC 60529 The product s touch screen has not been evaluated regarding the potential damaging effects from UV Use of the QuickPanel should be restricted to indoor ap...

Страница 38: ...are not exceeded In outdoor applications direct sun exposure may impose increased thermal loads on the QuickPanel leading to excessive temperature increases Cabinet design and orientation must be carefully considered to avoid exceeding the operational temperature limits These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials avoidi...

Страница 39: ...opening in the panel of the enclosure according to the specifications in the following diagram Mounting Clamp Locations To secure the QuickPanel View Control to a panel use the 16 included mounting clamps They hook into openings located on the top bottom and sides of the housing x 16 ...

Страница 40: ...to the housing openings as shown below 3 Ensure that the gasket is properly seated in the bezel channel and firmly tighten the clamp screws Note The torque range for the mounting clamp screws is 2 6 4 4 inch lbs 0 3 0 5 Nm The mounting clamps hold the unit in place by tension No drilling is required Caution Do not damage the gasket attached to the back of the QuickPanel This gasket provides the pr...

Страница 41: ...DC 48W power supply to the plug supplied with the QuickPanel View Control using 12 to 18 AWG For frame ground use shortest length 14 AWG wire to ground 2 Insert the plug into the power supply socket and securely tighten the attaching screws Note The torque range for the attaching screws is 4 6 inch lbs 0 45 0 68 Nm Bottom View Power Supply Plug ...

Страница 42: ...K 2402D 3 Field Replaceable Components Replace battery with Panasonic BR2032 only Use of another battery may present a risk of fire or explosion Do not remove or replace fuse when product is energized Replace with a 1A 125V rated fuse See Appendix A for additional information ...

Страница 43: ...lash CF port Universal Serial Bus USB 4 24 Using the USB port Ethernet 4 25 Setting an IP address Setting up access to a Windows network Accessing a remote resource on a Windows network Printing 4 32 Printing on USB or Network Shared printers Expansion Bus 4 35 Using the expansion bus to connect optional modules DIP Switches 4 36 Configuring startup behavior Memory 4 38 Adding Flash memory with a ...

Страница 44: ...or interface The display supports a resolution of 1024 by 768 pixels A backlight time is featured on all models You can extend the backlight life by turning off the backlight automatically 768 pixels 1024 pixels To adjust the display brightness 1 In the Control Panel double tap Display and choose the Brightness tab The Brightness dialog box appears 2 Drag the Brightness slider between Lowest and H...

Страница 45: ...turn off 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears 2 Select Auto turn off backlight while on external power 3 Tap OK to exit the control panel 4 To save the settings run the Backup utility as described in chapter 2 ...

Страница 46: ... calibrated this translates into a grid of touch cells on the face of the display A blunt stylus should always be used during calibration for greatest accuracy During normal operation use of a finger or a soft and pliable blunt object is recommended to preserve the maximum reliability of the touch screen 768 pixels 1024 pixels To calibrate the touch screen 1 In the Control Panel double tap Stylus ...

Страница 47: ...ose the Calibration tab 3 Tap the Recalibrate button A cross hair target is displayed Note For greatest accuracy it is recommended that you use a blunt stylus when calibrating the touch screen 4 Follow the directions given to calibrate the touch screen ...

Страница 48: ...anel Control Loaded Color TFT December 2011 GFK 2402D 4 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings 6 To save the settings run the Backup utility as described in chapter 2 ...

Страница 49: ...Stylus Properties dialog box appears 2 Choose the Double Tap tab 3 Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you double tap it double tap the grid again 5 Tap OK to finish 6 To save the settings run the Backup utility as described in chapter 2 ...

Страница 50: ...th the operating system and no setup is required To use an external keyboard simply plug and play A list of compatible devices keyboards USB mice compact flash cards etc may be found by visiting the Technical Support website see page iii for contact information Soft Input Panel The Soft Input Panel SIP is a touch screen version of a standard keyboard which can be used in place of a standard hardwa...

Страница 51: ...nel state check box 3 Select or clear the Show Input Panel in system tray check box 4 Tap OK 5 To save the settings run the Backup utility as described in chapter 2 The Soft Input Panel provides a standard QWERTY key layout with numeric keys at the top row as illustrated in the following picture Lower Case Upper case characters are accessed by pressing the SHIFT key once This is equivalent to hold...

Страница 52: ...lowing steps to reset the SIP to the center of the screen 1 In the Control Panel double tap Input Panel The Input Panel Properties dialog box shown above appears 2 Click Reset SIP location External Mouse optional Any USB mouse compatible with the QuickPanel View Control can be used as an input device for the unit The USB driver for the mouse is included with the operating system and no setup is re...

Страница 53: ...k supporting a TCP IP protocol A DB25S female connector mounted on the bottom of the enclosure provides standard signals as described in the following table 1 GND Frame Ground 14 VCC 5VDC 0 5A 2 TX EIA232C 15 TXB EIA485 3 RX EIA232C 16 RXB EIA485 4 RTS EIA232C 17 n c 5 CTS EIA232C 18 CSB EIA485 6 DSR EIA232C 19 ERB EIA485 7 SG Signal Ground 20 DTR EIA232C 8 DCD EIA232C 21 CSA EIA485 9 TRMRXB EIA48...

Страница 54: ...2 or 485 network Instead the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads may be connected The QuickPanel View or QuickPanel Control presents one unit load Interconnect media Always use twisted pair cabling and group complimentary signals into conductor pairs TXA with TXB for example Use a cable with a characteristic impedance of 100 ohms to 12...

Страница 55: ...ld and signal ground should be connected together at only one device closest to the earth ground connection The signal and frame grounds of the QuickPanel View QuickPanel Control are capacitively coupled but in some devices these ground references are connected together Connect Signal Ground pin 7 to Frame Ground pin 1 and then to earth ground on the QuickPanel View QuickPanel Control only in the ...

Страница 56: ... TX 4 n c 5 SG Signal Ground 6 n c 7 RTS 8 CTS 9 n c Shielding Shielded cable is required for compliance with CE Mark and FCC requirements The cable shield should be connected to the metal connector shell Shield and signal ground pin 5 of the 9 pin serial connector should not be connected directly together Working with COM ports To add a new remote networking connection 1 From the Start menu tap S...

Страница 57: ...t Direct Connection 5 Tap Next The Modem or Device dialog box appears depending on the connection type or 6 From the list choose the device or modem you want to use If a serial CF card is inserted it is available in the device list You can Configure your device or TCP IP Settings at this time if you wish 7 Tap Finish for direct connection Device dialog box or Next for dial up Modem dialog box ...

Страница 58: ...r 2011 GFK 2402D 4 If you are adding a dial up connection the following dialog box appears 8 Type the destination Country region code Area code and Phone number in the appropriate boxes 9 Select or clear the Force Long Distance or Force Local check boxes 10 Tap Finish ...

Страница 59: ...ctions The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for the new connection 4 Choose a connection type Select Virtual Private Network to configure a VPN connection Select PPP over Ethernet for a PPPoE connection 5 Tap Next The VPN or PPPoE Connection window appears depending on the connection type or ...

Страница 60: ...ge the default device properties 1 From either the Device or Modem dialog box tap Configure The Device Properties dialog box appears 2 In the Port Settings tab choose settings for all connection preferences 3 If the connection is for terminal emulation select or clear the terminal related check boxes You can use the QuickPanel View Control to emulate a terminal attached via a modem link Hayes comp...

Страница 61: ... settings from your network administrator 2 From either the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Settings The TCP IP Settings dialog box appears 3 Clear the Use server assigned IP address check box 4 Enter the TCP IP settings from your network administrator and then click OK ...

Страница 62: ...menu tap Programs then Communication and then tap Terminal The Terminal window appears 2 Double tap Make a New Session The Session Properties dialog box Communications tab appears 3 In the Session Name box type a name for your session 4 Enter the Country Code Area Code and Telephone number of the remote modem you will connect to ...

Страница 63: ...age selection box select the coding type to employ 7 Select the Inbound and or Outbound check boxes to add LF characters to each CR 8 Select the Vertical and or Horizontal check boxes to specify automatic scrolling 9 Tap OK 10 The new session is added to the Session window To save the settings run the Backup utility as described in chapter 2 ...

Страница 64: ...QuickPanel Control Loaded Color TFT December 2011 GFK 2402D 4 To start a terminal session 1 From the Start menu tap Programs then Communication and choose Terminal The Terminal window appears 2 Double tap the session you want ...

Страница 65: ...opy Project to Flash Card utility described in chapter 2 lets you transfer Proficy Machine Edition projects between QuickPanel View Control units via CF Cards No Compact Flash cards are supplied with the QuickPanel View Control A list of cards and other devices that have been tested and are compatible can be found by visiting the Technical Support website then selecting the Operator Interface cate...

Страница 66: ...2 Data 3 Data 4 GND A list of compatible devices keyboards USB mice compact flash cards etc may be found by visiting the Technical Support website Note These USB ports are defined as maintenance ports and are intended to be temporary connections used for configuration and upload download of software or data Use of a device in the USB port may compromise CE Mark and UL certifications Before using a...

Страница 67: ...pair UTP CAT 5 to the unit via the RJ45 connectors on the bottom of the enclosure LED indicators on the port indicate channel status Access to the port is possible either by Windows CE network communications or by your custom application The following diagram shows the location orientation and pin out of the Ethernet port On Packet received or transmitted On Channel connected OK 1 TX_D1 2 TX_D1 3 ...

Страница 68: ...connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration Manual method This is the default method for Port 2 You uniquely specify the numeric addresses for the QuickPanel View Control the Subnet Mask and the Default Gateway if applicable Note Use a crossover cable to connect the QuickPanel View Control directly to a PC W...

Страница 69: ...ction window appears 2 Select a connection and choose Properties The Built in Ethernet Port Settings dialog box appears 3 Select a method Obtain an IP address via DHCP automatic Specify an IP address manual 4 Enter the IP Address Subnet Mask and Default Gateway numbers obtained from your network administrator manual method only 5 Tap OK ...

Страница 70: ...as described in chapter 2 If the DHCP method was selected the network server will assign an IP address while the QuickPanel View Control is initializing You must be connected to the network After setting an IP address for the QuickPanel View Control you can access any network drives or shared resources for which you have permission ...

Страница 71: ...Panel double tap System The System Properties dialog box appears 2 On the Device Name tab in the Device name box type a unique name for your QuickPanel View Control In the Device description box type a description 3 Tap OK 4 In the Control Panel double tap Owner The Owner Properties dialog box appears ...

Страница 72: ...r 2011 GFK 2402D 4 5 On the Network ID tab type your User name Password and Domain 6 Tap OK 7 To save the settings run the Backup utility as described in chapter 2 Using Windows CE Explorer you can now access anything on your local network for which you have permission ...

Страница 73: ... MyRemoteComputer MyFolder specifies the folder named MyFolder on a computer with the name MyRemoteComputer 3 Press ENTER The resource specified is displayed as a collection of files and folders It can take a few moments to retrieve the data from your local network Note You can use the NET command from the shell to map a network resource to the QuickPanel View Control for frequent access The resou...

Страница 74: ...The control panel applet Printers is used to configure the port connection and other general printing options For fastest printing performance select draft mode and portrait orientation and disable color for print settings These setting also minimize the amount of memory needed to print a document The built in driver has a document spooling function to improve GUI performance This spooler supports...

Страница 75: ... close the dialog if it appears and choose a different printer Alternately you may be able to set the printer up as a network shared printer connected to another computer on your Ethernet network The port for the USB connected printer does not show on the printer configuration dialog s port list unless the USB printer is connected and compatible The port LPT1 will be shown in the port list when it...

Страница 76: ...ows CE does not support use of the server s IP for the server_name portion of the UNC Server_name is the text name of the printer server An IP address does not work here Printer_name is the printer port share name Do not confuse the port share name with the friendly printer name that may be displayed in a Windows desktop printer configuration To determine the share name either ask your IT departme...

Страница 77: ...e used when installing an expansion card Caution Disconnect the AC power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Caution Ensure all pins are properly aligned when inserting expansion cards M...

Страница 78: ...set to OFF by default in the factory DIP switch 2 is the Force Startup switch Turning this switch on forces the startup applications to run when the operating system is started When the switch is set to OFF the QuickPanel View Control operates normally displaying the startup splash screen You can skip running the startup applications by tapping the Don t run StartUp Programs button on the startup ...

Страница 79: ... behavior Caution Disconnect the AC power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Caution Do Not Allow conductive material liquid or solid to contact the electronics of the QuickPanel 1 Open...

Страница 80: ...long term storage of user application programs Another 16MB block is used to store the Windows CE operating system and is not directly accessible from Windows CE Explorer The operating system and all user application programs are transferred from Flash to DRAM for execution Any user additions to the Windows folder are retained in Flash Storage when the Backup utility is run FLASH memory has a limi...

Страница 81: ...l flash memory devices are named after their types of connection and order of attachment For example if you connect two flash memory devices one via the CF port and one via the fieldbus connector the first device connected is named PCFlash Storage the second PCFlash Storage2 At powerup a CF port device is recognized and named first Otherwise name depends on connection order SRAM Memory This 512 KB...

Страница 82: ...ables or data files is also provided by DRAM any data stored in DRAM will not be retained through a power cycle or reboot The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other depending on your specific application needs For example if you find that an application is short of memory use the System Properties dialog box to alter DRAM...

Страница 83: ... numerically The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move 3 Tap OK to apply the new setting 4 To save the settings run the Backup utility as described in chapter 2 Boot Loader ROM The Boot Loader ROM provides 512 KB of non volatile storage for the QuickPanel View Control s initialization program This program configures...

Страница 84: ...to equipment and injury to personnel Always use anti static precautions when accessing the interior of the QuickPanel View Control Caution Do Not Allow conductive material liquid or solid to contact the electronics of the QuickPanel To install additional DRAM 1 Disconnect AC power from the DC supply 2 With a small screwdriver carefully remove the top rear access cover 3 Insert the new DIMM careful...

Страница 85: ... s Power Properties control panel displays the status of the backup battery The Battery Very Low or Missing icon displays in the taskbar when the battery is either missing or very low To access the Power Properties control panel 1 In the Control Panel double tap Power The Power Properties dialog box appears ...

Страница 86: ...ower is enabled or disabled by installing or removing the battery accessed via the rear panel as shown in the following illustration Caution Disconnect the AC power from your DC power supply before opening the QuickPanel View Control Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions when accessing the interior of the QuickPanel View...

Страница 87: ... carrier noting the arrow on the carrier indicating the direction of removal To install a new battery 1 Disconnect power from the DC supply 2 Open the rear access panel Note Battery must be installed with positive side up 3 To install the battery insert one side of battery into upper side of battery clip then press other side into clip until snaps into place Warning Replace battery with Panasonic ...

Страница 88: ...n the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 In the Control Panel double tap Date Time The Date Time Properties dialog box appears Note Tap Apply after making changes in any box 2 To modify the date select the Date Time tab 3 Tap the year to choose a new year tap the month to choose a new month 4 Tap a date to specify the day of month 5...

Страница 89: ... utility as described in chapter 2 To display the time on the taskbar 1 From the Start menu choose Settings and then Taskbar and Start Menu Properties The Taskbar Properties dialog box appears 1 On the Taskbar Options tab select Show Clock 2 Tap OK An hours and minutes display now appears in the taskbar ...

Страница 90: ...l time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates It is recommended that you research any time server selection to ensure that it can meet your specific time server requirements More information and a list of SNTP time servers can be found at http support microsoft com kb 262680 If the time on the time ser...

Страница 91: ...g changes in any box 2 To add or modify SNTP settings select the SNTP tab 3 To enable SNTP ensure the Enable SNTP check box is selected 4 Enter the time server name in the Server s field 5 Set the Refresh Retry and Threshold parameters 6 Tap Update Now to update SNTP settings immediately 7 Tap OK to finish 8 To save the settings run the Backup utility as described in chapter 2 ...

Страница 92: ......

Страница 93: ...2in 70 7 mm Bezel dimensions Height 12 725 in 323 2 mm Width 15 7 in 398 8mm Depth 0 4 in 10 2 mm Weight 10 3 lb 4 67 kg DC Power Input Voltage 9 6 to 28 8 VDC Power Dip Tolerance 30 nominal input voltage 10msec Insulation Resistance 300Mohm 1000V frame ground to 0V 300Mohm 1000V frame ground to 24V Real Power 48 W Power Supply Conductor Size 12 to 18 AWG For compliance to CE Mark the isolated fra...

Страница 94: ... not field replaceable Luminance 500 NITS Front Panel Bezel Material Valox 3706 For material specifications visit www gepolymerland com Membrane Material Touch Screen Top Layer PET Polyester LEDs Bottom Power status indicator green with power applied flashes amber if both backlights fail Top Programmable tri color green red amber Touch Screen Type Resistive 12 bit Resolution X axis 1024 cells Y ax...

Страница 95: ...ximum DRAM 64 MB Maximum Devices Module 4 Bus Width 32 bits Bus Speed 100 MHz or faster Voltage 3 3 VDC CAS Latency CL 3 Refresh Type Self Refresh Cycle Time 64 ms maximum Error Correction Non ECC Error Detection No parity Buffering None Device Row Addressing 12 Address Lines A0 to A11 Expansion Ports Compact Flash Memory One slot Type I II supports 3 3v and 5v cards FieldBus One slot Universal Se...

Страница 96: ...Auto negotiate Full or half duplex RJ45 connectors Two status LEDs per connector Maximum cable length 100m Serial COM1 Speed Mounting hardware Fuse EIA232C EIA485 DP25S female 300 bps 115200 bps M2 6 jackscrew 1 0A 125V fast blow cartridge type Littlefuse part 154001 Serial COM2 Speed Mounting hardware EIA232C DP9P male 300 bps 115200 bps 4 40 screw ...

Страница 97: ...to peak displacement 57 500Hz 1 0g acceleration Operational Shock IEC 60068 2 27 15g 11ms sine wave Rated temperature limits refer to the ambient air temperature immediately surrounding less than 3 or 7 6 cm the QuickPanel Additional provisions for remaining within the stated limits must be considered where additional external thermal loads are imposed on the QuickPanel These could include large h...

Страница 98: ...2004 and 60079 15 2005 standards Explosive Atmospheres Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX II 3 G Certification in accordance with European directives refer to Declaration of Conformity Low Voltage Directive European Safety for Industrial Control Equipment CE Certification in accordance with European directives refer to Declaration of Conformity Ele...

Страница 99: ...This is further indicated when the bottom LED glows amber The LED will only light if both top and bottom backlights have failed Backlight timer expired Touch the screen to reactivate Pocket Internet Explorer Problem Suggested Remedy Cannot access any URLs when using a dial up connection to an ISP If you have previously set up an IP address on a local Ethernet Network it must be cleared Disconnect ...

Страница 100: ... delayed response to touch inputs Corrupted external flash drives may be corrected with Storage Manager See Storage Manager in chapter 3 Problem Suggested Remedy After adding expansion memory in the DIMM connector the system won t boot or if it does boot an error message is displayed When the system is first started observe the screen to notice any memory error messages from the boot loader If any...

Страница 101: ...n configuring 2 7 Dimensions bezel A 1 module A 1 panel cutout 3 3 DIP Switches 4 36 Display operation 4 2 specifications A 2 DRAM 4 40 adding 4 42 E Emulate PPC 2 16 Environmental requirements A 5 Ethernet ports operation 4 25 Expansion bus 4 35 Expansion memory diagnostics B 2 Expansion ports specifications A 3 F Firmware updates 1 4 Flash memory adding 4 39 operation 4 38 Front panel specificat...

Страница 102: ...nostics B 1 Power management 4 43 Power requirements A 1 Power supply connecting 3 5 Power up diagnostics B 1 Printing 4 32 Proxy server configuring 2 9 R Reboot 2 11 Remote resource accessing on a Windows network 4 31 Runtime setup 1 3 S Shutdown 1 4 SNTP setting 4 48 Software 2 5 Specifications A 1 SRAM memory 4 39 Startup behavior configuring 4 37 Storage Manager 2 12 System Information 2 13 T ...