background image

12

About the water softener system.

Breaking a Salt Bridge

Sometimes, a hard crust or salt bridge forms in
the salt storage area. It is usually caused by high
humidity or the wrong kind of salt. When the
salt bridges, an empty space forms between the
water and salt. Then salt will not dissolve in the
water to make brine.

If the brine tank is full of salt, it is hard to tell 
if you have a salt bridge. Salt is loose on top,
but the bridge is under it. The following is the
best way to check for a salt bridge.

Salt should be loose all the way to the bottom
of the tank. Take a broom handle or like tool,
and carefully push it down into the salt,
working it up and down. If the tool strikes 
a hard object (be sure it’s not the bottom or
sides of the tank), it’s most likely a salt bridge.
Carefully break the bridge with the tool.

Do not 

pound on the walls of the tank.

If the wrong kind of salt made the bridge, take
it out. Then fill the tank with nugget or pellet
salt only. In humid areas, it is best to fill with
less salt, more often to prevent a salt bridge
from forming.

A clean nozzle and venturi is needed for the 
water softening system to work properly. 

This

small unit makes the suction to move brine
from the salt storage area to the resin tank
during recharge. If it becomes plugged with
sand, dirt, etc., the water softening system 
will not work and you will get hard water.

To get to the nozzle and venturi, remove 
the water softening system top cover. Be sure
the water softening system is in service cycle
(no water pressure at nozzle and venturi).
Then, while holding the nozzle and venturi
housing with one hand, remove the cap. Lift
out the screen support and screen, then the
nozzle and venturi. Wash and rinse the parts in
warm water until clean. If needed, use a small
brush to remove iron or dirt. Also check and
clean the gasket.

NOTE:

Some models have a small flow plug

located in the nozzle and venturi, and/or 
a small cone shaped screen in the housing. 
Be sure to check and clean these parts, 
if your model is so equipped.

Carefully replace all parts in the correct order.
Lightly lubricate the o-ring seal with clean
silicone grease or petroleum jelly and place in
position.

Install and tighten the cap, by hand only.

Do not overtighten the cap.

Cleaning the Nozzle and Venturi Assembly

Push tool into salt
bridge to break

Pencil
mark

Broom
handle

Salt

Salt
bridge

Water level

2−5

 cm

 

IMPORTANT: 

Be sure small holes in the gasket are

centered directly over the small holes in the nozzle and
venturi housing.

*Install with numbered side up, concave side down.

Cap

O-ring seal

Screen support

Screen

Screen

Nozzle & Venturi

Nozzle & Venturi
housing

Gasket

*Flow plug

*Flow plug

Содержание GXOF18G

Страница 1: ...Tips 18 20 Consumer Support Parts list 87 www GEAppliances com 30500 General GXOF18G Euro Version 10 04 Write the model and serial numbers here Model ____________________________ Serial ____________________________ To find these numbers lift the cover and look on the rim below the control panel GXOF18G Owner s Manual Installation Instructions System tested and certified by NSF International agains...

Страница 2: ...NS PROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 37 C Do not install in direct sunlight Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances U...

Страница 3: ...er connections as required by state and federal codes Connect the softener to the main water supply pipe before or ahead of the water heater DO NOT RUN HOT WATER THROUGH THE SOFTENER Temperature of water passing through the softener must be less than 49 C Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 8 6 ...

Страница 4: ... m power cable If the outlet is remote up to 30 meters use 0 8 mm2 wire to connect Be sure the electric outlet and transformer are in an inside location to protect from wet weather Be sure the outlet is unswitched to prevent accidental shutoff If installing in an outside location you must take the steps necessary to assure the softener installation plumbing wiring etc are as well protected from th...

Страница 5: ...ll out for soft water service Push in for bypass Nut 2 not supplied Copper tube 3 4 2 not supplied Washer 2 not supplied Installation adapter 2 see above INLET Union not supplied 2 Optional 3 Valve Bypass Installation Illustration Adapters for this installation are not supplied with the softener Fig 1 CROSSOVER Use if water supply flows from the left Include single or 3 valve bypass Hard water Fro...

Страница 6: ...shown in Fig 1 page 5 If house water flows up from the floor level turn the bypass valve upside down as shown in Fig 3C If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint compound on all external pipe threads...

Страница 7: ...VATE this hose higher than the elbow on the brine tank IMPORTANT DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE NOTE This drain is for safety only If the cabinet brine tank should over fill with water the excess is carried to the drain 6 INSTALL GROUNDING CLAMP not included DANGER Failure to properly attach ground clamp could result in electrical shock If plumbing is metal to maintain electrical grou...

Страница 8: ...rains per gallon press MODE to accept NOTE If there is clear water iron in your water supply you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply You can get the grains per gallon gpg hardness of your water supply from a water analysis laboratory If you are on a municipal supply call your local water department To calculate the gpg hardness fr...

Страница 9: ...NALS If there is an error code detected the blue indicator light will flash 4 times every second the display will flash Err and the alarm will beep every 30 seconds from 8 00 AM to 8 00 PM to signal that the softener requires service The alarm can be turned off by pressing any button but the blue indicator light and display will continue to flash See page 14 for information to assist in troubleshooti...

Страница 10: ...diate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the drain This process takes approximately 2 hours 4 If after sanitization water from the house faucet tastes salty or has a slight color this is a preservative from the resin tank Turn on the cold soft water faucets and drain for a few minutes or until clear NOTE When the above sanit...

Страница 11: ...heater will fill with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard m...

Страница 12: ...he resin tank during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top cover Be sure the water softening system is in service cycle no water pressure at nozzle and venturi Then while holding the nozzle and venturi housing with one hand remove the cap Lift out ...

Страница 13: ...ystem begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When power is...

Страница 14: ... Time Features and Service If you are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical power to the outlet the water softening system transformer is plugged into 2 Is there sufficient salt in the storage tank 3 Is the softener bypass valve directing water for soft water ...

Страница 15: ...e the by pass valve and disconnect by pass valve from valve body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical data about the softener is available Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to di...

Страница 16: ...m contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and venturi not seated properly on gasket other inner valve defect rotor seal rotor and disc wave washer etc restricted drain check drain fitting and hose NOTE If water system pressure...

Страница 17: ...e water softening system resin clean it may also release corrosive fumes that weaken and shorten the life of some water softening system parts Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see the Specification Guidelines section clear water iron With clear water iron water from a fa...

Страница 18: ...on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass position Be sure the bypass valve stem is positioned properly with the knob in the OUT position Observe instructions on the decal at the end of the stem Check the position of bleed screw Valve drain hose pinched plugge...

Страница 19: ...Water Softener System section page 12 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Service Manually Initiated Electronics Diagnostics not regenerating section for troubleshooting procedures page 15 Call for service Sensor wire not plugged into See the Service Manually ...

Страница 20: ... air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose See page 14 for details in the control Unplug transformer Remove control cover release clips on side Check for loose incorrect wiring connections to electronic board or switch Reconnect as required Reassemble control cover Plug in Transformer Wait si...

Страница 21: ...softener s capacity Use clean water softening salts only at least 99 5 pure For best results use nugget pellet or coarse solar salts This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Refer to Use and Care Manual for further details on installation and maintenance user s responsibilities par...

Отзывы: