background image

10

This system conforms to NSF/ANSI 44 for the specific capacity claims as verified and substantiated by test data.
*

Testing was performed using pellet grade sodium chloride as the regenerant salt.

**

Efficiency rating is valid only at the lowest stated salt dosage and service flow rate. This softener was efficiency
rated according to NSF/ANSI 44.

*** Extent of iron removal may vary with conditions. The capacity to reduce clear water iron is substantiated by

independent laboratory test data. 
Refer to 

Cleaning Iron Out of the Water Softening System

section.

Step-by-step installation instructions.

Sanitizing Procedures

To complete the installation, do the following
sanitizing procedures.

Care is taken at the factory to keep your 
water softener clean and sanitary. Materials
used to make the softener will not infect or
contaminate your water supply and will not
cause bacteria to form or grow. However,
during shipping, storage, installing and
operating, bacteria could get into the 
softener. For this reason, sanitizing as 
follows is suggested when installing.

NOTE:

Sanitizing is recommended by the 

Water Quality Association for disinfecting.

1.

Be sure to complete all installation steps,
including programming the control.

2.

Pour about 22.ml (1

1

2

tablespoons) of

common 5.25% unscented household bleach
(Clorox, Linco, Bo Peep, White Sail, Eagle,
etc.) into the 

brinewell

. Refer to illustration

on page 5.

3. IMPORTANT: 

Press and hold for 3 seconds 

the faceplate 

RECHARGE

button to start 

an immediate recharge. 

RECHARGE

begins

to flash in the display. The bleach will be
drawn through the water softener and out
the drain. This process takes approximately 
2 hours.

4.

If, after sanitization, water from the house
faucet tastes salty or has a slight color, this is 
a preservative from the resin tank. Turn on 
the cold soft water faucets and drain for a 
few minutes or until clear.

NOTE:

When the above sanitizing regeneration

is over, all remaining bleach is flushed from the
conditioner and your house 

COLD

water supply

is fully soft immediately. However, your water
heater is filled with hard water and as hot water
is used, all remaining bleach is flushed from
the system and it will refill with soft water.
When all the hard water is replaced in the
water heater, hot only and mixed hot and cold
water will be fully soft. If you want totally soft
water immediately, after the above recharge,
drain the water heater until the water runs
cold.

WARNING:

If you do drain the

water heater, use extreme care as the hot
water could cause burns. Turn the water
heater off prior to draining.

Specifications/Dimensions

GXSF18G

Rated Capacity*

5.2 mols with 0.80 kg of salt

8.6 mols with 1.7 kg of salt

12.2 mols with 4.6 kg of salt

Rated Efficiency** 6.2 mols/kg @ 0.8 kg salt dose

Amount of High Capacity Resin (kg/liters)

15.1/18

Resin Tank Nominal Size (in., dia. x height)

10 x 21

Service Flow Rate (l/min)

26.5

Water Supply Maximum Hardness (gpg)

95

Water Supply Maximum Clear Water Iron (ppm)***

5

Water Pressure Limits (min.–max. bar)                                              1.4 - 8.6

Pressure Drop at Rated Service Flow (bar)

0.55

Water Temperature Limits (min.–max. °C)

4 - 49

Maximum Flow Rate to Drain (l/min)

8.3

Outlet

Inlet

8.6 cm

58.2 cm

36.8 cm

76.2 cm

Содержание GXOF18G

Страница 1: ...Tips 18 20 Consumer Support Parts list 87 www GEAppliances com 30500 General GXOF18G Euro Version 10 04 Write the model and serial numbers here Model ____________________________ Serial ____________________________ To find these numbers lift the cover and look on the rim below the control panel GXOF18G Owner s Manual Installation Instructions System tested and certified by NSF International agains...

Страница 2: ...NS PROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 37 C Do not install in direct sunlight Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances U...

Страница 3: ...er connections as required by state and federal codes Connect the softener to the main water supply pipe before or ahead of the water heater DO NOT RUN HOT WATER THROUGH THE SOFTENER Temperature of water passing through the softener must be less than 49 C Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 8 6 ...

Страница 4: ... m power cable If the outlet is remote up to 30 meters use 0 8 mm2 wire to connect Be sure the electric outlet and transformer are in an inside location to protect from wet weather Be sure the outlet is unswitched to prevent accidental shutoff If installing in an outside location you must take the steps necessary to assure the softener installation plumbing wiring etc are as well protected from th...

Страница 5: ...ll out for soft water service Push in for bypass Nut 2 not supplied Copper tube 3 4 2 not supplied Washer 2 not supplied Installation adapter 2 see above INLET Union not supplied 2 Optional 3 Valve Bypass Installation Illustration Adapters for this installation are not supplied with the softener Fig 1 CROSSOVER Use if water supply flows from the left Include single or 3 valve bypass Hard water Fro...

Страница 6: ...shown in Fig 1 page 5 If house water flows up from the floor level turn the bypass valve upside down as shown in Fig 3C If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint compound on all external pipe threads...

Страница 7: ...VATE this hose higher than the elbow on the brine tank IMPORTANT DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE NOTE This drain is for safety only If the cabinet brine tank should over fill with water the excess is carried to the drain 6 INSTALL GROUNDING CLAMP not included DANGER Failure to properly attach ground clamp could result in electrical shock If plumbing is metal to maintain electrical grou...

Страница 8: ...rains per gallon press MODE to accept NOTE If there is clear water iron in your water supply you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply You can get the grains per gallon gpg hardness of your water supply from a water analysis laboratory If you are on a municipal supply call your local water department To calculate the gpg hardness fr...

Страница 9: ...NALS If there is an error code detected the blue indicator light will flash 4 times every second the display will flash Err and the alarm will beep every 30 seconds from 8 00 AM to 8 00 PM to signal that the softener requires service The alarm can be turned off by pressing any button but the blue indicator light and display will continue to flash See page 14 for information to assist in troubleshooti...

Страница 10: ...diate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the drain This process takes approximately 2 hours 4 If after sanitization water from the house faucet tastes salty or has a slight color this is a preservative from the resin tank Turn on the cold soft water faucets and drain for a few minutes or until clear NOTE When the above sanit...

Страница 11: ...heater will fill with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard m...

Страница 12: ...he resin tank during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top cover Be sure the water softening system is in service cycle no water pressure at nozzle and venturi Then while holding the nozzle and venturi housing with one hand remove the cap Lift out ...

Страница 13: ...ystem begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When power is...

Страница 14: ... Time Features and Service If you are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical power to the outlet the water softening system transformer is plugged into 2 Is there sufficient salt in the storage tank 3 Is the softener bypass valve directing water for soft water ...

Страница 15: ...e the by pass valve and disconnect by pass valve from valve body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical data about the softener is available Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to di...

Страница 16: ...m contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and venturi not seated properly on gasket other inner valve defect rotor seal rotor and disc wave washer etc restricted drain check drain fitting and hose NOTE If water system pressure...

Страница 17: ...e water softening system resin clean it may also release corrosive fumes that weaken and shorten the life of some water softening system parts Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see the Specification Guidelines section clear water iron With clear water iron water from a fa...

Страница 18: ...on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass position Be sure the bypass valve stem is positioned properly with the knob in the OUT position Observe instructions on the decal at the end of the stem Check the position of bleed screw Valve drain hose pinched plugge...

Страница 19: ...Water Softener System section page 12 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Service Manually Initiated Electronics Diagnostics not regenerating section for troubleshooting procedures page 15 Call for service Sensor wire not plugged into See the Service Manually ...

Страница 20: ... air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose See page 14 for details in the control Unplug transformer Remove control cover release clips on side Check for loose incorrect wiring connections to electronic board or switch Reconnect as required Reassemble control cover Plug in Transformer Wait si...

Страница 21: ...softener s capacity Use clean water softening salts only at least 99 5 pure For best results use nugget pellet or coarse solar salts This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Refer to Use and Care Manual for further details on installation and maintenance user s responsibilities par...