background image

8. ADD WATER AND SALT TO THE BRINE TANK

• Lift the salt hole cover. Add about 11 litres of water into the 
  tank. Do not add into the brinewell.
• Fill tank with NUGGET, PELLET or coarse SOLAR water softener 
  salt with a purity of 99.5% or higher. 

Do not use

 rock, block, 

  granulated and ice cream-making salts, or 

salt with iron-removing 

 additives

  Maximum salt storage capacity is approxilately 45Kg.
  Keep the salt hole cover closed unless servicing the unit or 
 refi lling with salt.

NOTE:

 If the softener is installed in a humid basement or other damp 

area, it is better to 

fi ll the tank with less salt, more frequently

. 25 Kg. 

of salt will last for several months, depending on water hardness, 
family size and water softening system model.

9. CONNECT TO ELECTRICAL POWER

To gain access to the transformer/power cord assembly, remove the 
salt hole cover from the softener. Unclip the tabs on the rear of the 
top cover and rotate the cover upwards to remove. DO NOT PULL 
OR DISCONNECT WIRING.
• The softener works on 24 volt-50Hz electric power. The included 
  transformer changes standard 220 - 240 -volt AC house power to 
 24 volts.

Plug the transformer into a 220 - 240-volt outlet only

. Be sure the 

outlet is always live so it can not be switched off by mistake.
• Replace the top cover.
• Replace the salt hole cover.

7

4A. CONNECTING A RIGID VALVE DRAIN TUBE

To adapt a copper drain tube to the softener, buy a compression fi tting (garden hose thread x
1/2” O.D. tube) and needed tubing from your local hardware store.

5. INSTALL THE BRINE TANK OVERFLOW FITTINGS AND HOSE

• Insert the rubber grommet into the 2 cm diameter hole in the brine tank sidewall as shown
  in Fig. 5.
• Push the end of the hose adapter elbow into the grommet as shown in Fig. 5.
• Attach a length of hose (use remaining hose from Step 4) to the hose adapter elbow. Use a hose
  clamp to hold it in place.
• Locate the other end of the hose at the drain point. 

DO NOT ELEVATE

 this hose higher than

  the elbow on the brine tank.

IMPORTANT: DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE.
NOTE:

 This drain is for safety only. If the cabinet (brine tank) should over-fi ll with water, the excess

is carried to the drain.

6. INSTALL GROUNDING CLAMP (not included)

DANGER:

Failure to properly attach ground clamp could result in electrical shock.

If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, install
the ground clamp (not included) as shown in Fig. 6.
• Clean pipe with emery paper in the area where the clamp is to be installed.
• Install grounding clamps as shown, making sure clamps fi t freely around pipe.
• Make sure lock washer is in place.
• Handtighten screw, then one more full turn with screwdriver.

NOTE:

 When replacing an existing softener, also replace grounding clamps.

If removing softener completely, hard-plumb the water line with same type of pipes as the original
to assure plumbing integrity and ground continuity over the life of the home.

7. FLUSH PIPES, EXPEL AIR FROM SOFTENER, AND TEST YOUR INSTALLATION FOR
 WATER 

LEAKS

CAUTION:

To avoid water or air pressure damage to softener inner parts, be sure to

 

do the following steps in exact order.

• Fully open 2 cold soft water faucets nearby the softener.
• Place bypass valve in “bypass” position by pushing the stem inward.
• Fully open the house main water pipe shutoff valve. Observe a steady fl ow from both faucets
  opened in step A, above.
• Place bypass valve in the “service” position EXACTLY as follows. KEEP SOFT WATER
 FAUCETS OPEN.

SLOWLY pull or slide the valve stem (out) toward the service position, pausing several times to

  allow the softener to pressurize slowly.
• After about 3 minutes, open a HOT water faucet for 1 minute, or until all air is expelled, then
 close. NOTE:

 If water appears cloudy or has salty taste, allow to run for several more minutes, or

 until clear.

• Close all water faucets.
• Check your plumbing work for leaks and fi x right away if any are found. Be sure to observe
  previous caution notes.
• Turn on the gas or electric supply to the water heater. Light the pilot, if applicable.

Содержание GXOF18G

Страница 1: ...Tips 18 20 Consumer Support Parts list 87 www GEAppliances com 30500 General GXOF18G Euro Version 10 04 Write the model and serial numbers here Model ____________________________ Serial ____________________________ To find these numbers lift the cover and look on the rim below the control panel GXOF18G Owner s Manual Installation Instructions System tested and certified by NSF International agains...

Страница 2: ...NS PROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 37 C Do not install in direct sunlight Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances U...

Страница 3: ...er connections as required by state and federal codes Connect the softener to the main water supply pipe before or ahead of the water heater DO NOT RUN HOT WATER THROUGH THE SOFTENER Temperature of water passing through the softener must be less than 49 C Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 8 6 ...

Страница 4: ... m power cable If the outlet is remote up to 30 meters use 0 8 mm2 wire to connect Be sure the electric outlet and transformer are in an inside location to protect from wet weather Be sure the outlet is unswitched to prevent accidental shutoff If installing in an outside location you must take the steps necessary to assure the softener installation plumbing wiring etc are as well protected from th...

Страница 5: ...ll out for soft water service Push in for bypass Nut 2 not supplied Copper tube 3 4 2 not supplied Washer 2 not supplied Installation adapter 2 see above INLET Union not supplied 2 Optional 3 Valve Bypass Installation Illustration Adapters for this installation are not supplied with the softener Fig 1 CROSSOVER Use if water supply flows from the left Include single or 3 valve bypass Hard water Fro...

Страница 6: ...shown in Fig 1 page 5 If house water flows up from the floor level turn the bypass valve upside down as shown in Fig 3C If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint compound on all external pipe threads...

Страница 7: ...VATE this hose higher than the elbow on the brine tank IMPORTANT DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE NOTE This drain is for safety only If the cabinet brine tank should over fill with water the excess is carried to the drain 6 INSTALL GROUNDING CLAMP not included DANGER Failure to properly attach ground clamp could result in electrical shock If plumbing is metal to maintain electrical grou...

Страница 8: ...rains per gallon press MODE to accept NOTE If there is clear water iron in your water supply you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply You can get the grains per gallon gpg hardness of your water supply from a water analysis laboratory If you are on a municipal supply call your local water department To calculate the gpg hardness fr...

Страница 9: ...NALS If there is an error code detected the blue indicator light will flash 4 times every second the display will flash Err and the alarm will beep every 30 seconds from 8 00 AM to 8 00 PM to signal that the softener requires service The alarm can be turned off by pressing any button but the blue indicator light and display will continue to flash See page 14 for information to assist in troubleshooti...

Страница 10: ...diate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the drain This process takes approximately 2 hours 4 If after sanitization water from the house faucet tastes salty or has a slight color this is a preservative from the resin tank Turn on the cold soft water faucets and drain for a few minutes or until clear NOTE When the above sanit...

Страница 11: ...heater will fill with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard m...

Страница 12: ...he resin tank during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top cover Be sure the water softening system is in service cycle no water pressure at nozzle and venturi Then while holding the nozzle and venturi housing with one hand remove the cap Lift out ...

Страница 13: ...ystem begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When power is...

Страница 14: ... Time Features and Service If you are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical power to the outlet the water softening system transformer is plugged into 2 Is there sufficient salt in the storage tank 3 Is the softener bypass valve directing water for soft water ...

Страница 15: ...e the by pass valve and disconnect by pass valve from valve body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical data about the softener is available Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to di...

Страница 16: ...m contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and venturi not seated properly on gasket other inner valve defect rotor seal rotor and disc wave washer etc restricted drain check drain fitting and hose NOTE If water system pressure...

Страница 17: ...e water softening system resin clean it may also release corrosive fumes that weaken and shorten the life of some water softening system parts Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see the Specification Guidelines section clear water iron With clear water iron water from a fa...

Страница 18: ...on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass position Be sure the bypass valve stem is positioned properly with the knob in the OUT position Observe instructions on the decal at the end of the stem Check the position of bleed screw Valve drain hose pinched plugge...

Страница 19: ...Water Softener System section page 12 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine stuck See the Service Manually Initiated Electronics Diagnostics not regenerating section for troubleshooting procedures page 15 Call for service Sensor wire not plugged into See the Service Manually ...

Страница 20: ... air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose See page 14 for details in the control Unplug transformer Remove control cover release clips on side Check for loose incorrect wiring connections to electronic board or switch Reconnect as required Reassemble control cover Plug in Transformer Wait si...

Страница 21: ...softener s capacity Use clean water softening salts only at least 99 5 pure For best results use nugget pellet or coarse solar salts This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Refer to Use and Care Manual for further details on installation and maintenance user s responsibilities par...

Отзывы: