Chapter 4. Operation
28 | ADTS 405 R/F Mk2 Instruction Manual-English
© 2017 General Electric Company – All Rights Reserved.
shows the aim and measured values of ALT and CAS as a dual display. With any other
selected parameter the display shows the measured values of altitude and airspeed and, the
aim and measured value of the other selected parameter. Additional display modes are
available for certain options.
Note:
The ADTS 405 Mk2 automatically returns to the pressure display if left inactive in
any setup or menu type display for a period of more than 1 minute.
Figure 4-1: Single Display
Figure 4-2: Dual Display
1
Controlled or measured parameter.
2
Measured value.
3
“T” for timed rate of change.
4
Units of measurement.
5
“<” Pointer for parameter, i.e. aim that
changes on data entry.
6
Special messages, e.g. warm-up
period.
7
Aim (set-point or target) in control
mode, or “Leak Measure” when the
pressure controller is off.
1
Controlled or measured parameter.
2
Measured value.
3
“T” for timed rate of change.
4
Units of measurement.
5
“<” Pointer for parameter, i.e. aim that
changes on data entry.
6
Special messages, e.g. warm-up
period.
7
Aim (set-point or target) in control
mode, or “Leak Measure” when the
pressure controller is off.
Alt 5000 ft
Aim 5000<
WARMUP
1
2
4
3
6
6
7
5
Alt 5000 ft
Aim 5000<
CAS = 300.0 kts
Aim 300.0 WARMUP
1
2
4
3
6
5
7
Содержание Druck ADTS 405 F Mk2
Страница 2: ......
Страница 16: ...xiv ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 18: ...xvi ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 118: ...Chapter 7 Reference 100 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 134: ...Appendix A Menus 116 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 139: ......