Further Testing
© 2017 General Electric Company – All Rights Reserved.
ADTS 405 R/F Mk2 Instruction Manual-English | 67
6.8.6.1 USB ‘A’ Port
This port is for future function expansion only. Current use is for service purposes only.
6.8.6.2 USB ‘B’ Port
This port is for future function expansion only. Current use is for service purposes only.
6.8.6.3 RS 232 Port
This port is for future function expansion only. Current use is for service purposes only.
Note:
There are no operator accessible functions on any of the USB ports.
6.8.6.4 Ethernet Port
This port provides password controlled access to various sections of the internal ADTS filing
system. Areas available and relevant to operator activities are:
1.
The “Printed” records archive (see Section 7.2.17, “PRINT,” on page 78).
2.
The Test Programs archive (see Section 7.2.18, “EXECUTE TEST PROGRAM,” on
page 78.
6.8.6.5 IEEE 488 Port
The IEEE 488 port requires specialist knowledge of both IEEE 488 communications and test
programming for specified, authorized test procedures. Only qualified personnel should use
this facility, the test procedure must be authorized by the appropriate engineering authority.
If the display does not show that SCPI is selected, follow the procedure in Section 4.14.1,
“Enabling the IEEE 488 Option,” on page 45, then carry out the following procedure:
a.
Press [SCPI].
b.
Press
CLEAR/QUIT
, [DEVICE ADDRESS].
c.
Check the address displayed is 1.
d.
If not, press 1 on the numeric keypad and then
ENTER
.
e.
If any changes have been made, press
CLEAR/QUIT
until requested to accept the
changes, then press
ENTER
.
f.
The ADTS 405 Mk2 automatically restarts. When the display shows the main pressure
display, perform the test detailed in Section 6.8.6.6, “Programming a Test of the
IEEE 488 Facility,” on page 67.
6.8.6.6 Programming a Test of the IEEE 488 Facility
There are many different programs and items of equipment for communicating over the
IEEE 488 interface. In the following example, the user must be familiar with the IEEE 488 bus
controller to be used.
The following example commands can be used to check for correct operation of the IEEE 488
interface. Initialize the bus controller as follows:
a.
Set Address 1 as the talker listener address.
b.
Make sure that bus time-out periods are set sufficiently high (e.g, 5 seconds).
Содержание Druck ADTS 405 F Mk2
Страница 2: ......
Страница 16: ...xiv ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 18: ...xvi ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 118: ...Chapter 7 Reference 100 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 134: ...Appendix A Menus 116 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 139: ......