CONFIGURATION
© 2017 General Electric Company – All Rights Reserved.
ADTS 405 R/F Mk2 Instruction Manual-English | 95
4.
If ARINC limits are selected and any of the other limits are greater than the values of
the ARINC limits a display message requests confirmation that the lower, ARINC limit,
is to be used before the limit is saved.
Figure 7-1: ARINC 565 Operating Limits
7.4.13 SAVING LIMITS
When all limits and associated functions are set, press
CLEAR/QUIT
to exit the limit editing
screen. If changes have been made, the display shows a request for confirmation before
saving the changes. If the system detects any errors (e.g., duplicate aircraft names, values out
of range or editing system-defined limits) the display changes to the edit screen for the error
to be corrected.
7.4.14 CONFIG, [LIMITS], [EDIT LIMITS], [MAX LIMITS]
This function makes a set of maximum limits; a set of MAX limits can be edited using CONFIG,
[LIMITS], [EDIT LIMITS], [EDIT EXISTING] and saved with a new name. This is a quick method
Airspeed (kts)
Altitude (x1000 f
t)
60
55
50
40
30
20
15
10
1.0 Mach
-1
-10
0
100
190
200
300
450
400
500
600
Maximum altitude rate 20,000 ft/min
Maximum airspeed rate 1 Mach/min
Содержание Druck ADTS 405 F Mk2
Страница 2: ......
Страница 16: ...xiv ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 18: ...xvi ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 118: ...Chapter 7 Reference 100 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 134: ...Appendix A Menus 116 ADTS 405 R F Mk2 Instruction Manual English 2017 General Electric Company All Rights Reserved ...
Страница 139: ......