138
D90
PLUS
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
MODBUS MEMORY MAP
CHAPTER 2: MODBUS COMMUNICATION
D0D4
Remote DPS Input 1 Name
---
---
---
F205
"RemDPS Ip
1"
D0DA
...Repeated for Remote DPS Input 2
D0E4
...Repeated for Remote DPS Input 3
D0EE
...Repeated for Remote DPS Input 4
D0F8
...Repeated for Remote DPS Input 5
D102
...Repeated for Remote DPS Input 6
D10C
...Repeated for Remote DPS Input 7
D116
...Repeated for Remote DPS Input 8
D120
...Repeated for Remote DPS Input 9
D12A
...Repeated for Remote DPS Input 10
D134
...Repeated for Remote DPS Input 11
D13E
...Repeated for Remote DPS Input 12
D148
...Repeated for Remote DPS Input 13
D152
...Repeated for Remote DPS Input 14
D15C
...Repeated for Remote DPS Input 15
D166
...Repeated for Remote DPS Input 16
IEC 61850 GGIO6 Configuration (Read/Write Setting)
D210
IEC 61850 GGIO6 Master Device (2 items)
0 to 32
---
1
F079
0 (NONE)
D212
IEC 61850 GGIO6 Analog Value (4 items)
0 to 4294967295
---
1
F600
0
D21A
IEC 61850 GGIO6 Indication Operands (2 items)
0 to 65535
---
1
F300
0
IEC 61850 Report ConfRev (Read/Write Setting)
D260
IEC 61850 GGIO1 ConfRev
1 to 4294967295
---
1
F003
1
D262
IEC 61850 GGIO4 ConfRev
1 to 4294967295
---
1
F003
1
Mandatory (Read/Write Setting)
D280
Test Mode Function
0 to 1
---
1
F102
0 (Disabled)
D282
Test Mode Initiate
0 to 65535
---
1
F300
1
Mandatory (Read/Write Command)
D283
Clear All Relay Records Command
0 to 1
---
1
F126
0 (No)
Contact Outputs (Read/Write Setting) (128 Modules)
D290
Contact Output 1 Name
---
---
---
F205
“Cont Op 1"
D296
Contact Output 1 Operation
0 to 65535
---
1
F300
0
D297
Contact Output 1 Seal In
0 to 65535
---
1
F300
0
D298
Contact Output 1 Events
0 to 1
---
1
F102
1 (Enabled)
D299
Contact Output 1 Voltage Threshold
20 to 250
---
1
F001
20
D29A
Contact Output 1 Reserved
20 to 300
---
1
F001
125
D29B
...Repeated for Contact Output 2
D2A6
...Repeated for Contact Output 3
D2B1
...Repeated for Contact Output 4
D2BC
...Repeated for Contact Output 5
D2C7
...Repeated for Contact Output 6
D2D2
...Repeated for Contact Output 7
D2DD
...Repeated for Contact Output 8
D2E8
...Repeated for Contact Output 9
D2F3
...Repeated for Contact Output 10
D2FE
...Repeated for Contact Output 11
D309
...Repeated for Contact Output 12
Address Description
Range
Units
Step
Format Default
Содержание D90 Plus
Страница 4: ...iv D90PLUS LINE DISTANCE PROTECTION SYSTEM COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Страница 200: ...196 D90PLUS LINE DISTANCE PROTECTION SYSTEM COMMUNICATIONS GUIDE MODBUS MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION...
Страница 220: ...216 D90PLUS LINE DISTANCE PROTECTION SYSTEM COMMUNICATIONS GUIDE DNP POINTS CHAPTER 3 DNP COMMUNICATION...