78
GE INFORMATION
D20MX INSTRUCTION MANUAL
CHAPTER 5: CONFIGURING THE SOFTWARE
Result: The two files D20MX01-14X.zip and D20MX02-14X.zip appear in the
dialog.
3.4.
Select the appropriate file based on your decision in step 2.
3.5.
Click
OK
.
Result: On completion a pop-up message appears (e.g., Project D20MX01-14X
has been restored).
3.6.
Click
OK
.
4.
Open the SGConfig project containing the D20 or D200 device.:
4.1.
Click the
GE
button.
4.2.
Click the required SGConfig project in the
Recent Projects
list or select the
Open Project
menu item.
5.
Make a backup copy of the original D20 or D200 device configuration:
5.1.
Click the
Project
tab of
the original D20 or D200 device configuration
.
5.2.
Click the D20 or D200 device.
5.3.
Click the ribbon
Configure
group >
Edit
>
Copy
.
5.4.
Click a blank area on the page onto which the copy is to be placed.
5.5.
Click the ribbon
Configure
group >
Edit
>
Paste
.
Result: The Copying device window appears.
Result: Once completed a new device named COPY_OF_<original device
name> or <original device name>_COPY appears.
6.
Change the device type to D20MX.
6.1.
Click the
Project
tab of the original D20 or D200 device configuration.
6.2.
Click the D20 or D200 device.
6.3.
Click the ribbon
Configure
group >
Configuration
>
Hardware
>
Processor
>
Change Type
.
Result: The Change Device dialog appears.
6.4.
Select the
D20MX
type and click
OK
.
Result: A dialog is displayed indicating that the device type has been changed
successfully.
6.5.
Click
OK
.
Result: The device is now displayed as a D20MX.
7.
Select a D20MX processor from the D20MX Device Wizard:
7.1.
Click the
Project
tab of
the original D20 or D200 device configuration
.
7.2.
Click the D20MX device.
7.3.
Click the ribbon
Configure
group >
Edit
>
Properties
.
7.4.
Click
Next
until the Processor tab appears.
7.5.
Click the
Processor
tab >
General
sub-tab.
7.6.
From the Part Number field, click
Select
.
Result: The Select a Processor Card window appears.
7.7.
Select one of the three D20MX processor type part numbers (526-3001, 526-
3003 or 526-3005).
7.8.
Click
OK
,
Next
,
and
Finish
.
Result: The D20MX Device Wizard closes.
8.
Import the firmware definition from the factory default configuration (if you had opted
to upgrade the firmware in ConfigPro, then this step is not necessary):
8.1.
Click the Project tab of the original D20 or D200 device configuration.
8.2.
Click anywhere on the main page of the project to deselect the device.
Содержание D20MX
Страница 1: ...GE Digital Energy GE Information D20MX Processor Instruction Manual 994 0140 Version 1 4x Revision 1 ...
Страница 10: ...10 GE INFORMATION D20MX INSTRUCTION MANUAL ABOUT THIS DOCUMENT ...
Страница 32: ...32 GE INFORMATION D20MX INSTRUCTION MANUAL CHAPTER 1 BEFORE YOU START ...
Страница 90: ...90 GE INFORMATION D20MX INSTRUCTION MANUAL CHAPTER 5 CONFIGURING THE SOFTWARE ...
Страница 112: ...112 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX B STANDARDS PROTECTION ...
Страница 116: ...116 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX C FREQUENTLY ASKED QUESTIONS ...
Страница 148: ...148 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX D USING CONFIGPRO WITH D20MX ...
Страница 158: ...158 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX E SECURE CONNECTION FOR LOGICLINX ...
Страница 162: ...162 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX F LIST OF ACRONYMS ...
Страница 168: ...168 GE INFORMATION D20MX INSTRUCTION MANUAL INDEX ...