AV-300i Version 2 User’s Guide
—————— Function Description ——————
Ch.1
99
Multi speed src
Mlt spd 0 src
Mlt spd 0 source reference
Mlt spd s 0 src
Bit 0 source for the selection of the active Multi spd reference
Mlt spd s 1 src
Bit 1 source for the selection of the active Multi spd reference
Mlt spd s 2 src
Bit 2 source for the selection of the active Multi spd reference
Multi speed cfg
Mlt spd 0
Speed 0
Mlt spd 1
Speed 1
Mlt spd 2
Speed 2
Mlt spd 3
Speed 3
Mlt spd 4
Speed 4
Mlt spd 5
Speed 5
Mlt spd 6
Speed 6
Mlt spd 7
Speed 7
Multi speed mon
Mlt spd 0 mon
Speed 0 monitor
Mlt spd sel mon
Active selection monitor
Mlt spd out mon
Monitor for the multispeed Block output
1.8.5 Motopotentiometer Block (Moto Pot)
The Motopotentiometer Function is always active.
Furthermore, through the Motopot up src and Motopot down src sources it is possible to select the origin of the
Speed increase and decrease and of the command signals.
The Block offers also the possibility to invert the output reference. The Motopot invers src source selects the
inversion command.
The Speed Preset source, Motopot preset src, allows to select the Preset command. Such function can activate
a series of settings active on the input and/or output reference.
In the Block configurations it is possible to set, with Motopot lower lim and Motopot upper lim, the speed upper
and lower limit (in rpm and standard configured with 0 and 1000).
The Motopotentiometer acceleration and deceleration ramps are independent from those of the Ramp Block.
This Block, therefore, with Motopot acc dtl spd/time and Motopot dec dtl spd/time, allows to set the
Motopotentiometer Ramp.
Motopot init config allows to set the function stating the Motopotentiometer reference value when the Drive is
started. This parameter is selected among:
·
Power off
value at the turning off
·
Zero
zero rpm
·
Lower limit
Lower limit value
·
Upper limit
Upper limit value
Furthermore, Motopot preset cfg states the function of the Preset command. It is possible to select:
·
None
no operation
·
Input = 0
the input state is set at zero
·
Input = low lim
it sets on the input the speed lower limit
·
Input & ref = 0
it sets at zero the input and reference state
Содержание AV-300i
Страница 1: ...GEH 6641E Supersedes GEH 6641D GE Industrial Systems AV 300i TM Version 2 User s Guide ...
Страница 2: ......
Страница 12: ...GEH 6641E TABLE OF CONTENTS 12 ...
Страница 44: ...GEH 6641E Function Description 44 Ch 1 ...
Страница 174: ...GEH 6641E Function Description 174 Ch 1 ...