GEH-6641E
—————— Function Description ——————
26
Ch.1
I/O status
DI
7654321E
Standard digital inputs
00000000
DO
3210
Standard Digital outputs
0000
DIX BA9876543210
Expanded digital inputs
000000000000
DOX
76543210
Expanded digital outputs
00000000
1.2.3 Drive Advanced States (Advanced Status)
Advanced Status
DC link voltage
Drive DC link voltage
Magnetizing curr
Drive magnetizing current in Amps
Torque curr
Drive torque current in Amps
Magn curr ref [S,F]
Magnetizing current reference in Amps
Torque curr ref [S,F]
Torque current reference in Amps
Flux ref [S,F]
Drive flux reference in Webers
Flux [S,F]
Flux in Webers
Mot OL accum %
Accumulated timer counts of the motor I2t
BU OL accum %
Accumulated timer counts of the Scale Unit (BU) I2t
Drv OL accum %
Accumulated timer counts of the Drive I2t
Norm Std enc spd
Standard encoder speed (Std)
Norm Exp enc spd [F]
Expanded encoder speed (Exp)
Std enc position [F]
Raw accumulated encoder pulses (counts) of the Std encoder
Exp enc position [F]
Raw accumulated encoder pulses (counts) of the Exp encoder
Std sin enc mod
Module of sinusoidal encoder, “A” and “B” trace
HT sensor temp
Heatsink temperature °C
RG sensor temp
Temperature on the regulation card °C
IA sensor temp
Temperature of the heatsink incoming air temperature (available
from the size...)
Sequencer status
Sequencer status (State machine) see table below for status
CPU1 runtime
Time needed by the CPU1 (microprocessor)
CPU2 runtime
Time needed by the CPU2 (microprocessor)
The drive State Machine, controls the drive running and starting, accounting for protection & alarming, command
sequence, and reset status.
The waiting phase for the State Machine reset is showed in the Alarm List as Sequencer. The table below
displays various operation states by Sequencer status number. See section 1.12.2 , Alarm state for more details.
Sequencer status
State
1
Magnetization running
2
Magnetization completed, Stop
3
Start
4
Fast stop, Stop
5
Fast stop, Start
9
No alarm, drive is ready to accept all commands
10
Magnetization running and Start command already present
12
Alarm active
16
Alarm not active, waiting for reset
TAV3i020
Содержание AV-300i
Страница 1: ...GEH 6641E Supersedes GEH 6641D GE Industrial Systems AV 300i TM Version 2 User s Guide ...
Страница 2: ......
Страница 12: ...GEH 6641E TABLE OF CONTENTS 12 ...
Страница 44: ...GEH 6641E Function Description 44 Ch 1 ...
Страница 174: ...GEH 6641E Function Description 174 Ch 1 ...
Страница 295: ......