AV-300i Version 2 User’s Guide
—————— Function Description ——————
Ch.1
63
Table 1.5.3.1-1: Setup for Control from Keyboard (Factory Setup)
Parameter description
Index
Value
Comments
Command select
4002
Stop/FS & Spd=0
En/Disable mode
4004
I O keys
Dig Enable src
0156
Do not care
This source bypassed (AND logic)
Term StrStp src
0153
"DI 1 mon"
This source bypassed (AND logic)
Dig StrStp src
0157
Do not care
This source not used
Term Start src
9210
Do not care
This source not used
Term Stop src
9211
Do not care
This source not used
FStop src
0154
"NULL"
Fast stop not used
Jog cmd src
8015
"NULL"
Jog from the keyboard
Jog invers src
8018
"NULL"
Jog inversion from the keyboard
Spd 0 dis dly
4006
1000 msec
Spd 0 speed thr
3724
10 rpm
TAV35311
1.5.3.2 Control from Remote Pushbuttons
Command select = "Terminal edge"
This setup is useful for simple, standalone istallations where no PLC is used and the external relay logic is
minimal.
The keyboard/display module is not required, a LED module can be used instead. Momentary action pushbuttons
are used for Start, Stop, Jog and Jog inversion, with the mandatory Terminal Enable permissive.
En/Disable control logic and Jog are active.
No input is set for Fast stop command.
Parameters can be set as per example in table 1.5.3.2-1.
Complete wiring information for digital inputs may be found in the hardware reference section. The drive behaviour
is similar to the one for keyboard control (sect. 1.5.3.3.1), but for the fact that the four remote wired pushbuttons
replace the corresponding keys on the keyboard.
Of course there is no need to use a [Shift] button as remote buttons do not have multiple functions.
Table 1.5.3.2-1: Example Setup for Pushbutton Control
Parameter description
Index
Value
Comments
Command select
4002
Terminal edge
En/Disable mode
4004
Stop/FS & Spd=0
Dig Enable src
0156
Do not care
This source bypassed (AND logic)
Term StrStp src
0153
"NULL"
This source bypassed (AND logic)
Dig StrStp src
0157
Do not care
This source not used
Term Start src
9210
"DI 1 monitor"
Tie Start button to terminal 13
Term Stop src
9211
"DI 2 monitor"
Tie Stop button to terminal 14
FStop src
0154
"NULL"
Fast stop not used
Jog cmd src
8015
"DI 3 monitor"
Tie Jog button to terminal 15 (Jog used)
Jog invers src
8018
"DI 4 monitor"
Tie Jog invert button to terminal 36 (Jog used)
TAV35321
Содержание AV-300i
Страница 1: ...GEH 6641E Supersedes GEH 6641D GE Industrial Systems AV 300i TM Version 2 User s Guide ...
Страница 2: ......
Страница 12: ...GEH 6641E TABLE OF CONTENTS 12 ...
Страница 44: ...GEH 6641E Function Description 44 Ch 1 ...
Страница 174: ...GEH 6641E Function Description 174 Ch 1 ...
Страница 295: ......