GEH-6641E
—————— Function Description ——————
152
Ch.1
The PID Output Block is shown in the figure below.
PID FF mon
PID PI out mon
PID PD out mon
PID out mon
PID outS mon
PID out gain
PID out sign
+
X
X
-
PID output cfg
PID out sign
Output selection: Monopolar/Bipolar
PID out gain
Scale factor (output gain)
PID output mon
PID out mon
Direct output displaying
PID outS mon
Displaying of an output with a scale factor (gain setting)
1.15.7 Diameter Calculation (Diameter Calc)
This Function allows to perform a preliminary calculation of a coil diameter before starting the line. It allows to
avoid undesired mechanical sealings of the dancer.
The calculation is based on the moving of the dancer from the lower limit switch position to a central position as
compared to the winder angular moving during the initial phase.
The function is only available with a dancer reaction. The calculation result initializes the PI Block output.
Description:
APPL FUNCTION
PID
Diameter calc
Settings
Max deviation
Positioning spd
Gear box ratio
Dancer constant
Minimum diameter
DiaClc start src
Start ?
Press I key
Results
Diameter
Diacal PIO
DCDelta error
DCDelta pos
APPL FUNCTION
SAVE PARAMETERS