AV-300i Version 2 User’s Guide
—————— Function Description ——————
Ch.1
147
PI control mon
PID PI lock mon
PIGP ref mon
PI Pnorm gain
PI Inorm gain
PID PI out mon
PID Mlt PI 0 mon
PID Mlt PI 3 mon
PID MltPI selmon
APPL FUNCTION
SAVE PARAMETERS
The PI Control Block is shown in the figures below
PID Mlt PI 3 src
PID Mlt PI sel out
PID Mlt PI sel 0
PID Mlt PI 1
Int PID Mlt PI 2
Int PID Mlt PI 3
Int PID Mlt PI 0
Int PID Mlt PI 1
PID MtlPI selmon
PID I freeze src
PID FF mon
PID PI enab src
PID PI out mon
PI steady thr
PI Iinit gain
PI steady delay
PI Pinit gain
PI clamp bot
PI clamp top
PID PI Iock mon
PI I notm gain
PI P notm gain
X
+
+
PI P3 gain %
PI P2 gain %
PI P1 gain %
PI I3 gain %
PI I2 gain %
PI I1 gain %
P
I
REF
(REF)
PIGP tran21 band
PIGP tran32 band
PIGP tran21 h thr
PIGP tran32 l thr
PID FF mon
PI enable