40
—
Operating Procedures / Photos
Disassemble Valve
Unscrew the screw fixing the valve, unsolder the connecting
pipe of the valve, and remove the valve. (refer to Figure
8-45)
Disassemble Capillary
Unsolder the soldering points between the capillary and
other pipes to remove the capillary. (refer to Figure 8-46)
Disassemble Compressor
Unscrew the foot screw of the compressor and unsolder the
connecting pipe to remover the compressor. (refer to Figure
8-47)
Screw
Liquid
Valve
Gas
Valve
Screw
Figure 8-45
Capillary
Figure 8-46
Foot Nut
Figure 8-47