Mains Supply 3 x 380 - 480 VAC
AF-650 GP
600 HP
650 HP
750 HP
900 HP
1000 HP
1200 HP
Heavy Duty/Light Duty*
HD
LD
HD
LD
HD
LD
HD
LD
HD
LD
HD
LD
Typical Shaft output at
400 V [kW]
450
500
500
560
560
630
630
710
710
800
800
1000
Typical Shaft output at
460 V [HP]
600
650
650
750
750
900
900
1000
1000
1200
1200
1350
Typical Shaft output at
480 V [kW]
530
560
560
630
630
710
710
800
800
1000
1000
1100
IP21/Nema 1 and
IP54/Nema 12 Drive
Types without/with
options cabinet
61/ 63
61/ 63
61/ 63
61/ 63
62/ 64
62/ 64
Output current
Continuous
(at 400 V) [A]
800
880
880
990
990
1120
1120
1260
1260
1460
1460
1720
Intermittent (60 sec
overload)
(at 400 V) [A]
1200
968
1320
1089
1485
1232
1680
1386
1890
1606
2190
1892
Continuous
(at 460/ 480 V) [A]
730
780
780
890
890
1050
1050
1160
1160
1380
1380
1530
Intermittent (60 sec
overload)
(at 460/ 480 V) [A]
1095
858
1170
979
1335
1155
1575
1276
1740
1518
2070
1683
Continuous KVA
(at 400 V) [KVA]
554
610
610
686
686
776
776
873
873
1012
1012
1192
Continuous KVA
(at 460 V) [KVA]
582
621
621
709
709
837
837
924
924
1100
1100
1219
Continuous KVA
(at 480 V) [KVA]
632
675
675
771
771
909
909
1005
1005
1195
1195
1325
Max. input current
Continuous
(at 400 V ) [A]
779
857
857
964
964
1090
1090
1227
1227
1422
1422
1675
Continuous (at 460/
480 V) [A]
711
759
759
867
867
1022
1022
1129
1129
1344
1344
1490
Max. cable size,motor
[mm
2
(AWG
2)
)]
8x150
(8x300 mcm)
12x150
(12x300 mcm)
Max. cable size,mains
F1/F2 [mm
2
(AWG
2)
)]
8x240
(8x500 mcm)
Max. cable size,mains
F3/F4 [mm
2
(AWG
2)
)]
8x456
(8x900 mcm)
Max. cable size, load-
sharing [mm
2
(AWG
2)
)]
4x120
(4x250 mcm)
Max. cable size, brake
[mm
2
(AWG
2)
)
4x185
(4x350 mcm)
6x185
(6x350 mcm)
Max. external mains
fuses [A]
1
1600
2000
2500
Estimated power loss
at 400 V [W]
4)
9492
10647
10631
12338 11263 13201 13172 15436 14967 18084 16392 20358
Estimated power loss
at 460 V [W]
8730
9414
9398
11006 10063 12353 12332 14041 13819 17137 15577 17752
F3/F4 max. added los-
ses A1 RFI, CB or Dis-
connect, & contactor
F3 & F4
893
963
951
1054
978
1093
1092
1230
2067
2280
2236
2541
Max. panel options
losses
400
Weight,
Unit Size IP21, IP 54
[kg]
1004/ 1299
1004/ 1299
1004/ 1299
1004/ 1299
1246/ 1541
1246/ 1541
Weight Rectifier Mod-
ule [kg]
102
102
102
102
136
136
Weight Inverter Mod-
ule [kg]
102
102
102
136
102
102
Efficiency
4)
0.98
Output
frequency
0-600 Hz
Heatsink overtemp.
trip
95 °C
Power card ambient
trip
68 °C
* Heavy Duty = 160% torque during 60 s, Light Duty = 110% torque during 60 s
AF-650 GP Design Guide
60
4
Содержание AF-650 GP Series
Страница 5: ...AF 650 GP Design Guide 4 1...
Страница 53: ...AF 650 GP Design Guide 52 4...
Страница 97: ...Please note airflow directions 6 1 5 Mechanical Dimensions AF 650 GP Design Guide 96 6...
Страница 98: ...Please note airflow directions AF 650 GP Design Guide 97 6...
Страница 99: ...Please note airflow directions AF 650 GP Design Guide 98 6...
Страница 100: ...Please note airflow directions AF 650 GP Design Guide 99 6...
Страница 173: ...Max cable length 150 m AF 650 GP Design Guide 172 9...
Страница 179: ...AF 650 GP Design Guide 178 9...