Battery safety
The LOGIQ E10 is supplied with lithium ion batteries.
The lithium ion technology is significantly less hazardous to the environment than the lithium metal
technology used in some other batteries (such as watch batteries). Used batteries should not be placed
with common household waste products. Contact local authorities for the location of a chemical waste
collection program nearest you.
NOTE:
Regulations vary for different countries. Dispose of used batteries in accordance with local
regulations.
WARNING
WARNING
THE LOGIQ E10 BATTERIES HAVE A SAFETY DEVICE.
DO NOT ATTEMPT TO DIS-ASSEMBLE OR ALTER THE BATTERIES!
ALWAYS OBSERVE THE FOLLOWING PRECAUTIONS:
•
DO NOT short-circuit the batteries by directly connecting the negative terminals with metal objects.
•
DO NOT heat batteries or discard them into a fire.
•
DO NOT expose batteries to temperatures over 50 °C. Keep batteries away from fire and other heat
sources.
•
DO NOT charge batteries near a heat source, such as, a fire or heater.
•
DO NOT leave batteries in direct sunlight.
•
DO NOT pierce batteries with a sharp object, hit it, or step on it.
•
DO NOT use damaged batteries.
•
DO NOT apply solder to batteries.
•
DO NOT connect batteries to an electrical power outlet.
•
DO NOT immerse batteries in water or allow them to get wet.
CAUTION
USE ONLY BATTERIES APPROVED BY GE AS SUITABLE FOR USE WITH THE LOGIQ E10
ULTRASOUND SYSTEM.
CAUTION
TO PREVENT BATTERIES FROM BURSTING OR IGNITING, OR FUMES FROM THE BATTERIES
CAUSING EQUIPMENT DAMAGE, ALWAYS OBSERVE THE FOLLOWING PRECAUTIONS:
•
DO NOT place batteries into a microwave oven or pressurized container.
•
If a battery leaks or emits an odor, remove it from all possible flammable sources.
•
If a battery emits an odor or heat, is deformed or discolored, or in a way appears abnormal during
use, recharging or storage, immediately remove it and stop using it.
NOTE:
If you have any questions about the batteries, consult your local GE representative.
•
Storage of the battery pack:
-
Short-term
(less than 1 month): between 0 °C (32 °F) and 50 °C (122 °F)
-
Long-term
(more than 3 months): between 10 °C (50 °F) and 35 °C (95 °F)
When charging batteries for the first time after long-term storage, recover the battery pack to original
performance through repeating several cycles of full charging and discharging.
Содержание 5935000E10
Страница 1: ...LOGIQ E10 Basic Service Manual 5750007 1EN Rev 1 Version R1 2018 GENERAL ELECTRIC COMPANY ...
Страница 2: ......
Страница 3: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL i Important Precautions TRANSLATION POLICY ...
Страница 4: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL ii ...
Страница 5: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL iii ...
Страница 6: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL iv ...
Страница 7: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL v ...
Страница 8: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL vi ...
Страница 9: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL vii ...
Страница 10: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL viii ...
Страница 11: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL ix ...
Страница 12: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL x ...
Страница 13: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL xi ...
Страница 14: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL xii ...
Страница 18: ...DIRECTION 5750007 1EN REVISION REV 1 LOGIQ E10 BASIC SERVICE MANUAL xvi This page was intentionally left blank ...
Страница 34: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL xxxii Hardware Kit 9 49 ...
Страница 776: ...DIRECTION 5750007 1EN REV 1 LOGIQ E10 BASIC SERVICE MANUAL Index 4 ...
Страница 777: ......
Страница 778: ... 2018 General Electric Company GE Healthcare 9900 Innovation Drive RP 2156 Wauwatosa WI 53226 USA www gehealthcare com ...