NX-592E
Installation Manual
6
Installation
Installation requires you to position the module, connect all wires and mounts, and optionally install a case
tamper.
Installation guidelines
Use the following guidelines when installing the module:
•
NetworX panels support a maximum of one Wireless Gateway per system.
•
Use four-conductor, 22- or 18-gauge stranded wire to connect the module to the panel (see
Table 2
).
•
Mount the module as close to the panel as possible. The module draws a maximum of 65 mA
(continuous) and up to 1600 mA (instantaneous peaks) from the panel.
•
Do not exceed the panel’s total output power when using panel power for bus devices and hardwired
sensors (refer to specific panel installation instructions).
Tools and supplies needed
•
Slotted and Phillips screwdrivers
•
Drill (3/8” drive) and drill bits
•
Wire-cutter/stripper
•
Four-conductor, 22-gauge or larger stranded wire
•
Modem (sold separately on NX-592E-BO)
•
Modem antenna and mounting screws (included)
•
#6 panhead screws and wall anchors (four each included)
Locating the module
Use the following guidelines when locating the module:
•
Locate the module near an outside wall, preferably on an upper level.
•
Leave 12 to 18 inches of space near the module antenna jack.
•
Avoid locating the module in areas with excessive metal or electrical wiring, such as a furnace or
utility room.
•
Make sure the antenna is pointing up.
Table 2.
Maximum wire length
Gauge
Max. wire length to panel
22 ga.
40 feet
18 ga.
90 feet