ENTRA EB control board (S/M) it is designed to work in Interlock mode (either for single than double door)
with connection with an electronic control board of the same series.
Opening of a door, in the Interlock mode, it can just happen if the other door is not moving, if it is making
any movement.
To interlock two operators after wiring them according the instructions on the side page, follow these
steps:
1.
Select a priority for opening, (if sensors give input to open at same time to both doors, it is required to set a
priority for opening):
o
Chose the control board WITH PRIORITY
o
Chose the control board WITHOUT PRIORITY
SET MASTER WITH PRIORITY:
15
AUX-IN 1
2 = Interlock door with priority
17
AUX-OUT 1
1 = Status door open
2.
SET MASTER WITHOUT PRIORITY:
15
AUX-IN 1
3 = Interlock door without priority
17
AUX-OUT 1
1 = Status door open
In the case of contemporary opening signals, it will open the selected door selected WITH PRIORITY.