57
ENTRA
EB
30
Polarity input
AUX OUT
0 = NA (Normally Open)
1 = NC (Normally Close)
0
31
Weight of the wings
0 = Automatic (achieved during LP)
1 = level LOW
2 = level MEDIUM
3 = level HIGH
0
32
Force level during
RESET and LP
procedure
RANGE: 0 ÷ 9
(0 = minimum÷ 9= maximum)
5
33
Opening angle
reduction in
percentage
RANGE: 0% ÷ 50% (step of 1%)
0
34
Closing in mode
other than manual
0 = Closing by motor.
1 = Closing by spring
0
35
DDA opening speed
0 = Low Energy
1 = speed as parameters 1 e 2
0
36
Batteries mode
0 = standard (only spring)
1 = continuous operation
2 = antipanic
0
37
START 2
configurations
0 = Functionality as described at page 43
1 = DDA opening: active only in manual mode
2 = DDA opening: active in all mode
0
38
Not used
0
39
Approaching speed
RANGE:
5°/s ÷ 15°/s (step of 1°/s)
8
40
Partial opening
RANGE:
50%÷90% (step of 2%)
70
41
Function in spring
closing mode
0 = Stop Movement
1 = Reopening by motor
0