79
ENTRA
EB
SIGNAL
DESCRIPTION
E1
Door needs self learning procedure (see Paragraph “Start up”)
E5
Missing Main-Key
E6
Error in the configuration of the monitoring sensors
(Need to set parameter 18)
E7-5
Electrical overcurrent detection
E7-6
Time-out Movement (greater than
60”)
E7-A
Overload power tension out of tolerance
E8-1
Error Test connection Motor and Encoder
(Verificare la connessione del Motore e dell’Encoder).
E8-8
Diagnostic error Encoder
E8-A
Over Current
E9
Activation safety function
N.B.:
following errors:
E3 / E4 / E7-2 / E7-3 / E7-4 / E7-7 / E7-8 / E7-9 / E7-b / E7-C / E7 -F / E8-2 / E8-3 / E8-4 / E8-5 /
E8-6 / E8-7 / E8-9 / E8-b.
They are related to temporary anomalies. If they persist replace the control board and send it to Entrance
Dynamics with the error code indicated.
WARNING!
This product falls within the scope of the Directive 2012/19 / EU concerning the management of waste for
electrical and electronic equipment. (RAEE). The appliance must not be disposed of with domestic waste as it is made
of different materials that can be recycled to suitable structures. Inquire through the municipal authority regarding the
location of the ecological platforms suitable to receive the product for disposal and the subsequent correct recycling. It
should also be remembered that, upon purchase of an equivalent appliance, the distributor is obliged to collect the
product for disposal free of charge. The product is not potentially dangerous for human health and the environment, it
does not contain harmful substances as per Directive 2011/65 / EU (RoHS), but if abandoned in the environment it
negatively impacts on the ecosystem.
The crossed-out bin symbol indicates the compliance of this product with the regulations regarding waste
for electrical and electronic equipment. The abandonment in the environment of the equipment or the
illegal disposal of the same are punished by law.
C187340_03_MAN_SM_E_28_10_20
Содержание ENTRA EB
Страница 1: ...1 ENTRA EB ENTRA EB SWING DOOR OPERATOR INSTALLATION MANUAL ENGLISH ...
Страница 32: ...32 ENTRA EB Arm in closed position ...
Страница 37: ...37 ENTRA EB 4 Refit switching and control board insert cable connector in the dedicated electric clamp ...
Страница 67: ...67 ENTRA EB 28 WIRING AND USE OF INTERLOCK With priority Without priority ...