PEDIATRIC HAL®
|
User Guide
72 | Routine Maintenance
6. ROUTINE MAINTENANCE
6.1 CLEANING THE VEINS
It is strongly recommended to clean and dry the forearm vasculature at the
end of each simulation session to prevent mold or clogs.
1.
To clean and dry the IV arm, fill the filling
syringe with a mixture of water and isopropyl
alcohol (70:30 ratio), and connect the fill
syringe and the drain tube to the arm.
2.
Push the water and isopropyl alcohol mixture
until the fluid that exits the drain tube is clear.
3.
Once the fluid runs clear, fill the syringe with
air and push the air through the vasculature.
NOTE: Pushing air through the veins
helps to remove any residual fluid
and dries the vasculature.
4.
Disconnect the drain tube and filling syringe.
WARNING: Do not store the simulator with fluids in the veins. Doing so may
lead to molding and may damage the internal electronics.