Appendix A – MAs for VF-25 Voice Module
Intraplex VF-25 Voice Module
Version 7.1, November 2009
GatesAir, Inc.
A-29
Intraplex Products
Table A-34. MA-308 Switch Settings
Channels 1-4
Transmit (T)
Receive (R)
Gain
1
In
Out
-23 dB Transmit circuit
1
Out
In
-23 dB Receive circuit
2
In
Out
-23 dB Transmit circuit
2
Out
In
-23 dB Receive circuit
3
In
Out
-23 dB Transmit circuit
3
Out
In
-23 dB Receive circuit
4
In
Out
-23 dB Transmit circuit
4
Out
In
-23 dB Receive circuit
All Channels
In
In
-23 dB Transmit & Receive circuits
All Channels
Out
Out
No additional attenuation
A.2.3.6 Installation
To install the MA-308 module adapter, perform these steps:
1.
At the rear of the chassis, insert the adapter into the same slot position in which the VF-25 module
has been installed.
2.
Once it is seated securely, secure the unit with screws provided.
3.
Plug the connector into the adapter.
A.2.4
MA-308B Four-Wire, RJ-45 Connector
The MA-308B module adapter combines
●
Modular connectors
●
Monitoring jacks
●
Tandem application attenuators
The MA-308B is designed to use with 4-wire E&M Voice Frequency Modules in any Intraplex Products
multiplexer. It provides eight connectors for signal connection and monitoring, as well as eight
switches for control of additional signal attenuation. The switches are marked T=Transmit and
R=Receive, for each of the four channels (Figure A-19).
Содержание Intraplex VF-25
Страница 2: ......
Страница 10: ......
Страница 11: ...No header here 1 2 GatesAir Inc Intraplex Products This page is left blank intentionally...
Страница 12: ......
Страница 26: ......
Страница 27: ...No header here 2 14 GatesAir Inc Intraplex Products This page is left blank intentionally...
Страница 28: ......