or overheat. When temperature is below 50˚C, the safety control system will stop the stove 
automatically.   
 
For general problems, the possible reasons and the solutions are as following    After solving 
problems, start the stove again:   
problems 

reason 

solution 

1.  The  blower  doesn’t 
work  after  pressing  the 
start bottom.   

No power in stove or in 
the control panel. 

Check the power and wires. 

3.

 

No 

feed 

after 

igniting. 
A. Three lights are bright 
and flash. 

Feed unit is blocked. 
Auger  motor  doesn’t 
work. 
 

Check the auger is blocked or not. 
Check  auger  motor  is  blocked  or  not. 
And the wires break or not. 
Check the fasten screw between auger 
and motor loose or not.       

B. Three lights are bright 
but no flash. 

No fuel in the hopper. 
The clock unit breaks.       

Fill the fuel into the hopper. 
Change the clock unit. 

C. The red light is bright 
and flash but other lights 
aren’t bright. 

The  high  temperature 
switch disconnects. 
The  high  temperature 
switch breaks. 

Tight  the  high  temperature  switches 
connection.   
Change the high    temperature switch   

D.  Three  lights  aren’t 
bright. 

No 220V power. 
Pellet  feeder  is  power 
off. 
The  wires  of  start  and 
clock unit loose or break. 

Check the 230V power. 
Turn on the auger motor switch. 
Check the wires of start and clock unit 
or change the unit.   

3.  After  ignition  the 
power is off 15min late. 

Pellet feeder unit is off or 
pellet is too little. 
50˚C 

temperature 

switch  breaks  or  the 
connection  wires  of 
switch loose. 

Check  the  pellet  feeder  unit  and 
restart. 
Check the connection wires or change 
the 50˚C temperature switch. 
 

4.  orange  and  lazy  fire, 
piled  pellet,  carbon  on 
the glass 

Lack  of  air  intake  for 
burning.   

Clean the block in gate bar. 
Adjust  the  knob  of  convection  blower 
and increase the air intake. 
Check  the  door  and  window  glass 
gasket sealed or not.   
Check  the  air  intake  pipe  and  venting 
pipe  blocked  or  not,  and  clean  it. 
Change  to  the  big  diameter  pipes  if 
pipes  are  too  long  to  affect 
combustion. 

5.  The  fire  put  out  and 
power 

is 

off 

automatically.   

The hopper is empty. 
No fuel feed. 
The fuel feed is too little. 

Put fuel into the hopper. 
refer to (2) 
Increase the fuel feed. 

Содержание HP24

Страница 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Страница 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Страница 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Страница 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Страница 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Страница 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Страница 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Страница 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Страница 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Страница 10: ...Page 10 19...

Страница 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Страница 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Страница 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Страница 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Страница 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Страница 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Страница 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Страница 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...

Страница 19: ...Page 19 19...

Отзывы: