USE AND MAINTENANCE
ENGLISH
g
cod. G19502880
49
.
X 2
fig. 53
fig. 54
fig. 50
fig. 51
fig. 52
.
5) Switch on the panel (Fig. 50) and wait until the initialization process is completed (approx.
8 to 10 seconds).
6) Fill the metering rollers with product before starting the cal test. Press the “CAL TEST”
button (Z in Fig. 49) and hold it pressed for approx. 5 seconds. Then, release the button
and empty the containers from product. Finally, position the containers back under the
metering units.
Now, the equipment is ready for the cal test.
7) Press the “CAL TEST” button (Z in Fig. 49) and hold it pressed for the time required to
collect the necessary quantity of product:
10 to 15 kg – standard seeds and fertilizer;
3 to 5 kg – fine seeds.
During this operation, the display shows the image of the metering roller moving and a
simulation of product dropping into the containers (Fig. 51).
NOTE: during the test, motor rotation CANNOT be stopped and resumed. When the
test button is released, the cal test can be stopped, or resumed from step 7
after emptying the containers.
8) Release the “CAL TEST” button (Z in Fig. 49) to stop the motor.
The panel display shows the image of the metering roller not running and a quantity of
product in the containers (Fig. 52). It also shows a theoretical quantity calculated according
to the set parameters.
9) Weigh the collected product and use the numeric keypad to enter the net value of the
product weight in the panel (Fig. 53).
WARNING!
Use the correct unit (Kg or gr) and pay attention to the position of the
decimal point (8.35 Kg = 8350 gr).
10) Press ENTER
twice to confirm the parameter value.
The display shows the test results (Fig. 54):
- previous cal factor;
- new cal factor;
- correction percentage;
- new max. speed calculated.
11) Press ENTER
to confirm and update the system with the new product cal factor
or ESC to cancel the operation.
The display goes back to the SETUP menu for further cal checks (see section 4.5.1).
Press MAIN to go back to the main page.
WARNING: after the test, close the spouts (Fig. 48).