USE AND MAINTENANCE
ENGLISH
g
cod. G19502880
44
fig. 32
fig. 31
fig. 33
fig. 34
fig. 35
Table 5
SETUP
OPERATOR SETUP
Drill Setup
«
»
If the operator knows the
Cal Factor
or
T.G.W.
values, he can enter them directly in the
system in menu «
» (Fig. 31) without undergoing the Cal test.
The display shows the following constant parameters (Fig. 32):
•
Cal Fact
: this is the product metering factor equal to the quantity (kg) of product obtained
with one turn of the metering roller. If this value is known, enter it using the keypad. Press
ENTER to confirm or run a “cal test” as instructed below.
•
T.G.W.
(“thousand grain weight”): this is the weight of 1000 seeds. Enter the actual weight
of 1000 grains using the numeric keypad. Then, press ENTER to confirm. This parameter
must only be set if “grains/ml” is the selected unit (see section 4.4.1 “Customise”).
•
Max Sp
: this is the max. working speed to guarantee correct seed distribution (it is
automatically calculated by the system).
•
: this procedure is used to correct the product metering factor (Cal Fact): it can be
applied only after 1 ha of drilled area.
NOTE: this procedure IS NOT RECOMMENDED!!! Adhere to the procedures described
below (section 4.5.1).
•
: this procedure is used to correct the product metering factor (Cal Fact) with reference
to a desired quantity of product set in the system.
According to this procedure, start the motor by pressing the ENTER button, and collect the
set quantity of product in a container.
Stop the motor and weigh the collected product. Then, use the keypad to enter the net value
of the product weight.
Press ENTER twice to confirm the parameter value. The display shows the test results, i.e.
the previous and the new metering factor, the correction percentage and the new max.
speed calculated.
Press ENTER to confirm or ESC to cancel the operation.
SETUP
OPERATOR SETUP
Cal Check
«
»
This procedure is used to correct the product metering factor (Cal Fact) (Fig. 33).
This is the same procedure as that described in the section “Drill Setup”.
SETUP
OPERATOR SETUP
Alarms
«
»
This menu is used to set the alarms regarding fan rotation and hopper level (Fig. 34 & 35).
Enter the following parameters:
- alarm: min. threshold for fan rotation (see Table 5);
- alarm: max. threshold for fan rotation (see Table 5);
- alarm: hopper level: ON / OFF.
Press the buttons
to find the desired parameter. Enter the new values recommended
in Table 5 using the keypad. Then, press ENTER
to confirm.
Press the button
to enable (ON) or disable (OFF) the hopper level alarm.
FAN ROTATION SPEED (rpm)
Min.
Max.
Standard seeds
3700
3900
Fine seeds
2500
3000
Fertilizer (up to 200 Kg/Ha)
3500
3700
Fertilizer (over 200 Kg/Ha) 3700 3900