USE AND MAINTENANCE
ENGLISH
g
cod. G19502880
39
fig. 17
fig. 18
fig. 19
A
fig. 16
fig. 15
2
3
4
5
1
7
6
8
9
PA1 - GRINTA
100
150
200
250
300
350
400
450
500
4
6
8
10
12
working speed (km/h)
max. quantity (kg/ha)
3,0 m;
A
B
C
D
E
F
A
4,0 m;
B
4,5 m;
C
5,0 m;
D
6,0 m;
E
9,0 m;
F
PA2 - CENTAURO (GRINTA)
100
150
200
250
300
350
400
450
500
4
6
8
10
12
working speed (km/h)
max. quantity (kg/ha)
4,5 m;
A
5,0 m;
B
6,0 m;
C
9,0 m;
D
A
B
C
D
Table 2
Table 3
B
A
4.0 PROGRAMMING AND USE
When the monitor is switched on, it shows the MAIN page (Fig. 15), which is commonly used during operation. Use the buttons (F in
Fig. 1) to view the following pages: RATE page where the quantity parameters of product to be distributed are set; SETUP page for
programming purposes; INFO page for consulting the number of hectares drilled and the product quantity distributed.
4.1 MAIN PAGE
This page is divided into 5 areas where the following parameters are
displayed (Fig. 15):
1)
working speed
;
2)
status of TRAMLINING system
;
3)
fan rotation speed
;
4)
current metering (kg/ha)
;
5)
motor operation
;
6)
motor ON/OFF:
this parameter is used to manually stop or resume
seed dispensing when required;
7)
“pre-start” function
: to prepare the equipment for the first metres
of seed dispensing;
8)
stop automatic count of passes for tramlining
;
9)
manual count of passes for tramlining
.
Note! The motor operation parameters may change according to
seed dispensing configurations (Fig. 16):
A) two products (seeds-fertilizers) using two independent motors;
B) one single product using two motors.
4.1.1 WORKING SPEED
The working speed displayed is the average speed calculated every 3 seconds.
The system is supplied with an alarm indicating low or high working speed:
- when the equipment is in work position and its speed is inferior to 0.5 km/h, a warning light
blinks on the MAIN page (Figure 17), and a buzzer goes off;
- when the equipment is in work position and its speed exceeds the admissible dispensing
speed range, a warning light blinks on the MAIN page (Figure 18), and a buzzer goes off.
When a new metering value is set on the
RATE
page, the system calculates and shows the
new max. working speed at which the machine can distribute the product (Fig. 19). Speed
is calculated according to the quantity of product to be distributed, the drill width, the calibration
and max. motor rotation speed.
The actual quantity of product that the pneumatic system on the machine can dispense
depends on the drill width and the working speed as illustrated in the following diagrams
(
Table 2 and Table 3
).
Note! Press the function key near the icon (A in Fig. 19) to go back to the RATE page.