5
Operating instructions
With the switch nr. 12 you can connect or disconnect the fan
from the mains electrical system.
-
With the switch in the ‘0’ position the fan is not switched
on.
-
With the switch in the ‘I’ position the fan is connected to
the mains electricity supply but it will not run. It will start run-
ning only after the upper loading door has been closed.
Note:
The upper door is open in order to load the
wood and the fan is off. Proceed with igniting
the wood as described in paragraph 6.4.
The opening of the loading door activates a control timer, by
means of a microswitch, whose default value is of 30 minutes,
which can be increased by another 30 (this can only be car-
ried out by qualified personnel).
If the boiler does not reach the minimum temperature (about
65°C)within the foreseen time (control timer), the fan and re-
cycling pump will be turned off.
Panel connected to the mains electricity supply, but… the
boiler is not running.
Therefore repeat the lighting procedure.
12
13
12
13
Central heating temperature adjustment
The adjustment of the system water’s temperature in the GA-
SOGEN G3 2S boiler is obtained by rotating the knob position
32 in a clockwise direction to increase the temperature and in
an antic-clockwise direction to lower it.
The temperature can be adjusted between 75°C minimum and
85°C maximum.
Activation of the safety thermostat
IMPORTANT
:
The GASOGEN G3 2S safety thermostat’s
activation command is positioned on the front of the con-
trol panel.
The thermostat in position 31 reactivates the wood fired boi-
lers operation.
To gain access to it in case the boiler goes into lock-out, un-
screw the plastic cap with the help of a screwdriver; after ha-
ving reset it, replace the plastic cap.
32
31