Generali Informations

The user or the person in charge has to instructed on the use and operation of his heating system, in particular:
§ Hand over these instructions to the end user, together with any other literature regarding this appliance placed

inside the envelope contained in the packaging.

The user has to keep these documents in a safe place in

order to always have them at hand for future reference.

§ Inform the user on the importance of air vents and of the flue outlet system, stressing the fact that it is absolutely

forbidden to make any alterations to the boiler.

§

Inform the user how to check the system’s water pressure as well as informing him how to restore the correct
pressure.

§

Explain the function of time and temperature controls, thermostats, heating controls and radiators, to ensure
the greatest possible fuel economy.

§

Remind the user that it is obligatory to service the appliance at least annually and to carry out a combustion
analysis in compliance with the schedule indicated in the national Codes of Practice.

§

If the appliance is sold or transferred to another owner or if the present user moves home and leaves the
appliance installed, ensure yourself that the manual always follows the appliance so that it can be consulted by
the new owner and/or installer.

4. INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER/SERVICE EN-

GINEER

5. SAFETY WARNINGS

WARNING!
The installation, adjustment, and servicing of this appliance must be carried out by a competent, quali-
fied person and installed in accordance with the current standards and regulations. Failure to correctly
install this appliance could cause injury to persons, animals or damage to property. The manufacturer
shall not be held liable for any injury and/or damage.

DANGER!
NEVER try to carry out any repairs or service work on the boiler on your own initiative.
Servicing or repairs of the appliance must be carried out by qualified service engineers;
UNICAL recommends drawing up a service contract.
Bad or irregular servicing could compromise the safe operation of the appliance, and could cause injury
to persons, animals or damage to property for which UNICAL shall not be held liable.

Modifications to parts connected to the appliance
Do not carry out any modifications to the following parts:
-

the boiler

-

to the gas, air, water supply pipes and electrical current

-

to the flue pipe, safety relief valve and to the central heating’s drainage pipe

-

to the constructive components which influence the appliance’s safe operation

Smell of gas

If you smell gas follow these safety indications:
 Do not turn on or off electrical switches
 Do not smoke
 Do not use the telephone
 Close the On/Off gas cock
 Open all windows and doors where the gas leakage has occurred
 Inform the gas society or a company specialized in installing and servicing heating systems

Explosive and easily inflammable substances

Do not use or leave explosive or easily inflammable material (as for example: petrol, paint, paper) in the room
where the appliance has been installed.

Содержание G3 50 2S

Страница 1: ...Wood Fired Boiler Gasogen 29 93kW User Operating Instructions...

Страница 2: ...e according to the foreseen scopes it is necessary to carefully follow the instructions indicated in this manual 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with...

Страница 3: ...ustment and servicing of this appliance must be carried out by a competent quali fied person and installed in accordance with the current standards and regulations Failure to correctly install this ap...

Страница 4: ...the switch in the I position the boiler is connected to the mains electricity supply green led light illuminated and is ready to operate The recycle pump functions Mode selection keys With the switch...

Страница 5: ...about 65 C within the foreseen time control timer the fan and re cycling pump will be turned off Panel connected to the mains electricity supply but the boiler is not running Therefore repeat the lig...

Страница 6: ...sure If it is an open circuit system the pressure does not have to be restored as this occurs automatically via the water level regu lator inside the water tank If it is a sealed circuit system refer...

Страница 7: ...g this switch you can connect or disconnect the boiler from the mains electricity supply With the switch in the 0 position the boiler is not switched on green led light off With the switch in the I po...

Страница 8: ...he upper loading door has been closed With the switch 22 it is possible to select the operation mode wood or the back up gas or oil fired boiler Place the switch into the 0 position wood firing mode N...

Страница 9: ...or disconnect the sy stem pump boiler load from the mains electrical system With the switch in the 0 position the system pump is not switched on With the switch in the II position the system pump is...

Страница 10: ...u can connect or disconnect the fan from the mains electrical system Set the switch in the I position the fan is powered electrically but it will not run It will start running only after the upper loa...

Страница 11: ...ce the plastic cap The safety thermostat can intervene in case of boiler tempera ture overheating You can avoid this happening by lowering the working thermostat see above If the boiler s safety therm...

Страница 12: ...st be placed as previously described 6 3 CHECKSTO CARRY OUT BEFORE FIRING THE BOILER Before firing the boiler carry out the following checks Check that the On Off gas valve positioned upstream of the...

Страница 13: ...ore the quantity of wood burnt whilst the secondary air completes the combustion P Primary air box S Secondary air box 1 Metal ring air adjuster P S 1 S1 P1 S S P P1 C USEFUL SUGGESTIONS and LOADING E...

Страница 14: ...noisy excess of primary air P The flame must not be too small lack of primary air P If the ash does not falls down properly increase the pri mary air P If too much ash falls down reduce the primary ai...

Страница 15: ...aused by the wood s moisture content and the way the boiler is used PRECAUTIONS TO TAKE DURING BOILER OPERA TION After every air adjustment wait 5 to 10 minutes before making a new adjustment Once the...

Страница 16: ...loading Every week Remove carefully all the residues of combustion accumula ted in the fire box Clean with the brush supplied the triangular passes of the combustion chamber Remove the ashes from the...

Страница 17: ...ushing rod when the loading door is opened In this way the smoke accumulated in the firebox is aspirated and sent to the chimney directly The bypass in conclusion allows the smoke to be discharged at...

Страница 18: ...sed for long periods see paragraph 6 7 Use thicker wood logs Use up all the wood before loading a new batch Problem The boiler does not reach the requested temperature The flame is small and there is...

Страница 19: ...er does not remain unused for long periods see paragraph 6 7 Use bigger logs Use up all the wood before loading a new batch Problem The boiler does not reach the requested temperature The flame is sma...

Страница 20: ...9 5 6 8 7 8 7 1 2 4 3 10 2 1 2 4 3 9 10 2 6 5 8 7 Spare parts GASOGEN G3 25 2S GASOGEN G3 40 2S GASOGEN G3 50 2S GASOGEN G3 65 2S GASOGEN G3 80 2S Gasogen 20...

Страница 21: ...Spare parts GASOGEN G3 25 2S GASOGEN G3 40 2S GASOGEN G3 50 2S GASOGEN G3 65 2S GASOGEN G3 80 2S 14 11 13 12 15 16 17 21...

Страница 22: ...12 26955 Stone cast iron bars insulation kit 13 26956 Stone cast iron bars insulation kit X X 13 12350 Cast iron bars insulation kit 14 12352 Cast iron bars insulation kit X X X X PUC0420 Triangular...

Страница 23: ...ing Pty Ltd ABN 90 446 545 923 51 Assembly Tullamarine Vic 3043 Australia PO Box 356 Tullamarine Vic 3043 Australia 61 3 9330 3300 61 3 9310 5655 sales automaticheating com au Telephone Facsimile Emai...

Отзывы: