1 - SYMBOLS USED IN THIS MANUAL

When reading this manual, particular care has to be given to the parts marked with the followings symbols:

NOTE! Suggestions for the
user

WARNING! Indicates a potentially
dangerous situation for the product
and the environment

DANGER! Indicates se-
rious danger for your
personal safety and for
your life

2 - A CORRECT USE OF THE APPLIANCE

The GASOGEN G3 2S appliance has been designed utilizing today’s heating technology and in compliance with
the current safety regulations.
However, following an improper use, dangers could arise for the safety and life of the user or of other people, or
damage could be caused to the appliance or other objects.
The appliance is designed to be used in pumped hot water central heating systems.
Any other use of this appliance will be considered improper.
UNICAL declines any responsibility for any damages or injuries caused by an improper use; in this case the risk
is completely at the user’s responsibility.
In order to use the appliance according to the foreseen scopes it is necessary to carefully follow the instructions
indicated in this manual.

3 - WATER TREATMENT

The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned.

In hard water areas where the main water can exceed 15°f total hardness, a scale reducing device is recom-

mended. The choice of this device has to be made taking into consideration the characteristics of the water.

We recommend you to check the state of cleanliness of the domestic hot water heat exchanger at the end of the

first year and subsequently every two years; in this occasion check the state of wear of the anode.

CONTENTS

1 Symbols used in

this man ual .................................................................................................................................................... 2

2 Correct use of

the appliance

..................................................................................................................................................... 2

3 Water

treatment

......................................................................................................................................................................... 2

4 Information to be passed over to the end user by the installer/servicing engineer ................................................................. 3
5 Safety warnings ......................................................................................................................................................................... 3
6 Operating instructions ............................................................................................................................................................... 4

6.1 Standard controlpanel ....................................................................................................................................................... 4
6.2 Optional control panel ........................................................................................................................................................ 7
6.3 Checks to carry out before firing the boiler ...................................................................................................................... 12
6.4 Boiler start-up ................................................................................................................................................................... 12
6.5 Combustion air adjustment .............................................................................................................................................. 13
6.6 Checks to carry out after first start-up ............................................................................................................................. 14
6.7 Warnings ........................................................................................................................................................................... 15
6.8 Summer operation ............................................................................................................................................................ 15
6.9 Servicing ........................................................................................................................................................................... 16
6.10 Fault finding ..................................................................................................................................................................... 18
-.-

Easily replaceable spare parts ......................................................................................................................................... 20

Содержание G3 50 2S

Страница 1: ...Wood Fired Boiler Gasogen 29 93kW User Operating Instructions...

Страница 2: ...e according to the foreseen scopes it is necessary to carefully follow the instructions indicated in this manual 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with...

Страница 3: ...ustment and servicing of this appliance must be carried out by a competent quali fied person and installed in accordance with the current standards and regulations Failure to correctly install this ap...

Страница 4: ...the switch in the I position the boiler is connected to the mains electricity supply green led light illuminated and is ready to operate The recycle pump functions Mode selection keys With the switch...

Страница 5: ...about 65 C within the foreseen time control timer the fan and re cycling pump will be turned off Panel connected to the mains electricity supply but the boiler is not running Therefore repeat the lig...

Страница 6: ...sure If it is an open circuit system the pressure does not have to be restored as this occurs automatically via the water level regu lator inside the water tank If it is a sealed circuit system refer...

Страница 7: ...g this switch you can connect or disconnect the boiler from the mains electricity supply With the switch in the 0 position the boiler is not switched on green led light off With the switch in the I po...

Страница 8: ...he upper loading door has been closed With the switch 22 it is possible to select the operation mode wood or the back up gas or oil fired boiler Place the switch into the 0 position wood firing mode N...

Страница 9: ...or disconnect the sy stem pump boiler load from the mains electrical system With the switch in the 0 position the system pump is not switched on With the switch in the II position the system pump is...

Страница 10: ...u can connect or disconnect the fan from the mains electrical system Set the switch in the I position the fan is powered electrically but it will not run It will start running only after the upper loa...

Страница 11: ...ce the plastic cap The safety thermostat can intervene in case of boiler tempera ture overheating You can avoid this happening by lowering the working thermostat see above If the boiler s safety therm...

Страница 12: ...st be placed as previously described 6 3 CHECKSTO CARRY OUT BEFORE FIRING THE BOILER Before firing the boiler carry out the following checks Check that the On Off gas valve positioned upstream of the...

Страница 13: ...ore the quantity of wood burnt whilst the secondary air completes the combustion P Primary air box S Secondary air box 1 Metal ring air adjuster P S 1 S1 P1 S S P P1 C USEFUL SUGGESTIONS and LOADING E...

Страница 14: ...noisy excess of primary air P The flame must not be too small lack of primary air P If the ash does not falls down properly increase the pri mary air P If too much ash falls down reduce the primary ai...

Страница 15: ...aused by the wood s moisture content and the way the boiler is used PRECAUTIONS TO TAKE DURING BOILER OPERA TION After every air adjustment wait 5 to 10 minutes before making a new adjustment Once the...

Страница 16: ...loading Every week Remove carefully all the residues of combustion accumula ted in the fire box Clean with the brush supplied the triangular passes of the combustion chamber Remove the ashes from the...

Страница 17: ...ushing rod when the loading door is opened In this way the smoke accumulated in the firebox is aspirated and sent to the chimney directly The bypass in conclusion allows the smoke to be discharged at...

Страница 18: ...sed for long periods see paragraph 6 7 Use thicker wood logs Use up all the wood before loading a new batch Problem The boiler does not reach the requested temperature The flame is small and there is...

Страница 19: ...er does not remain unused for long periods see paragraph 6 7 Use bigger logs Use up all the wood before loading a new batch Problem The boiler does not reach the requested temperature The flame is sma...

Страница 20: ...9 5 6 8 7 8 7 1 2 4 3 10 2 1 2 4 3 9 10 2 6 5 8 7 Spare parts GASOGEN G3 25 2S GASOGEN G3 40 2S GASOGEN G3 50 2S GASOGEN G3 65 2S GASOGEN G3 80 2S Gasogen 20...

Страница 21: ...Spare parts GASOGEN G3 25 2S GASOGEN G3 40 2S GASOGEN G3 50 2S GASOGEN G3 65 2S GASOGEN G3 80 2S 14 11 13 12 15 16 17 21...

Страница 22: ...12 26955 Stone cast iron bars insulation kit 13 26956 Stone cast iron bars insulation kit X X 13 12350 Cast iron bars insulation kit 14 12352 Cast iron bars insulation kit X X X X PUC0420 Triangular...

Страница 23: ...ing Pty Ltd ABN 90 446 545 923 51 Assembly Tullamarine Vic 3043 Australia PO Box 356 Tullamarine Vic 3043 Australia 61 3 9330 3300 61 3 9310 5655 sales automaticheating com au Telephone Facsimile Emai...

Отзывы: