5. The display is powered entirely by four “AA” penlight alkaline
cells instead of a combination of a lithium battery and AA
cells. This allows the end user to be able to fully service any
battery problems.
6.
The fiber optic connector is field replaceable, so if it is broken
or fails, the display can be quickly returned to service.
7. The display has a built in SpillStop transmitter, so an additional
SpillStop module is no longer required when connecting the
gauge to an 815 SpillStop controller.
8. The display has the ability to drive a remote transmitter for
applications which require the transfer of the data from the
gauge to another piece of equipment.
Software Revision 6.02
1. See
Chapter 8
to determine the software revision.
2. Prior to revision 6.02, the alarm outputs would all go to an
open circuit condition if the gauge is in a failure mode such as
no light, bad light or sun.
3. Since revision 6.02, alarms 3 and 4 will go to a closed circuit
condition during a failure mode. This change has been made
so that if the gauge is being used with the 815-JBPC junction
box, the pump will default to an off condition in the event of
a gauge failure.
4.
The SpillStop output is not affected by this change, so a
connected SpillStop will still default to an overfill condition in
the event of a gauge failure.