Page 21
810-PS2 Manual
1. The display will change to “PL F” or “SS F” depending on
whether the display is currently programmed for a plastic or
stainless steel float. When this happens, remove the magnet
and release the button.
2. If no further action is taken, the display will revert to normal
operation after about 5 seconds with no change in the float
programming. This is useful if you just want to check the
current float programming.
3.
To change the float programming, press and release the button
before the 5 second time expires, otherwise start again at step
3. Each time the button is pressed the float type will change.
4.
When the correct float type is shown, programming is
complete. After 5 seconds of no button activity, the display
will show “Stor” for 2 seconds if the float type has been
changed, indicating that the new float type has been stored.
5. The display will then return to normal operation.
Содержание SeeLevel ProSeries II 810-PS2