Page 41
In order to ensure that the platen reed switches are in
their proper location, you must ensure that the distance of
the magnet is the correct distance away from the switch
(located inside the upper platen).
1) Enter the “LEVEL/REED SW” mode:
a) With the controller display ON and either
displaying the current menu item or displaying
“OFF” PRESS and HOLD the button for 3
seconds. Controller will display previously selected
menu item and its corresponding item number OR
“Standby / Menu Item”.
b) PRESS the AND arrow buttons TOGETHER.
“CONFIGURE” will appear in the display.
c) PRESS the 2X. “CALIBRATION” appears.
d) PRESS the button. “LEVEL/REED SW” appears.
e) PRESS the button. “NO” will begin to flash.
f) PRESS the button. “NO” will change to “YES”.
g) PRESS the button. “YES” will stop flashing.
h) Press the GREEN button to lower the platen.
2) Remove the reed switch grease caps.
TO SET THE REED SWITCHES
3) Remove the reed switch locking caps.
4) Using the Platen Adjusting Tool, screw the magnet
down (clockwise) UNTIL the controller sounds a hi
pitched BEEP.
5) Screw the magnet UP (counter-clockwise) UNTIL the
hi-pitched BEEP STOPS.
6) Screw the magnet counter-clockwise one, (1), more
full turn (360˚) .
7) Repeat the procedure for the opposite reed switch.
8) After setting the reed switches as desribed, you must
perform a Forced Auto Calibration.
Press the GREEN button to raise the platen.
9) PRESS until “AUTO GAP FORCE” appears.
10) PRESS the button. “NO” will begin to flash.
11) PRESS the button. “NO” will change to “YES”.
12) PRESS the button. The platen will immediately lower
and reset its internal measurements.
1. Remove Platen Cover.
2. Remove Wire Nuts
from reed switch leads.
3. Mark wires for easy
reconnection.
4. Remove reed switch
bracket with 5/64 allen
wrench.
5. Install new reed
switch on the bracket,
aligning its edges
with the edges of the
bracket, as shown.
6. Confirm that your
positioning gauge is
in-square by checking
it against the corner
of the platen arm
as shown. Bend
for compliant fit if
necessary.
7. Reinstall reed switch
bracket using the
positioning gauge.
Align pushing in the
direction shown, and
tighten securly.
8. Reconnect wires with
wire nuts, and reinstall
the Platen Cover.
Warning:�Reed�switches�carry�high�voltage
Isolate grill from all electrical power. Disconnect Power Cords.
TO CHANGE THE REED SWITCH
Содержание MWE3S