PART #4526396 (03/30/10)
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
SERVICE MANUAL
Page 11
SPECIFICATIONS
SUPPLY�
REQUIRED
TOTAL��
kW��
LOAD
LOADING:�(kW/
PHASE)
NOMINAL�AMPS�PER�LINE
208V�/�220V�/�240V
208V�/�60Hz
220V�/�60Hz
240V�/�60Hz
L1/L2 L1/L3 L2/L3 L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT�1
10.0
3.25
3.25
3.25 28.0 28.0 28.0 26.3 26.3 26.3 24.0 24.0 24.0
GAS�INPUT
GAS
MAX�INPUT��
(NET)�PER��
BURNER��
(BTU/H)
TOTAL�INPUT�
RATING
(BTU/H)
INJECTOR��
SIZE
AIR�SHUTTER�
SETTING
(MM)
SUPPLY��
PRESSURE
(IN�WC)
BURNER��
MANIFOLD�
PRESSURE
(IN�WC)
NATURAL�GAS
32,000
96,000
#35
4.8
3.5
3.5
PROPANE
32,000
96,000
#43
4.8
3.5
3.5
3N~�400V�
50Hz
TOTAL�kW��
LOAD
LOADING:�(kW/PHASE)
NOMINAL�AMPS�PER�LINE
MENNEKES�
PLUG�&�
RECEPTACLE�
MAY�BE�
REQUIRED
L1/L2
L1/L3
L2/L3
L1
L2
L3
10.0
3.25
3.25
3.25
14.1
14.1
14.1
Type 748
GAS�INPUT�
GAS�GROUP
MAX�INPUT�
(NET)��PER�
BURNER�(kW)
TOTAL�
INPUT�
RATING�
(kW)
INJECTOR��
SIZE
AIR�
SHUTTER��
SETTING�
(mm)
SUPPLY��
PRESSURE��
(mbar)
BURNER��
PRESSURE��
(mbar)
VOLUMETRIC��
GAS�RATE
G20 NG
8.9
26.7
2.79mm (#35)
4.8
20/25
8.7
0.940 m
3
/h
G25 NG
2.79mm (#35)
4.8
20
8.7
G31 LPG
8.9
26.7
2.26mm (#43)
4.8
37/50
8.7
0.69 kg/h
NET�HEATING�VALUE�BY�GAS�GROUP
G20
G25
G31
34.02 MJ/m
3
; 0.555 SG
29.25 MJ/m
3
; 0.613 SG
88.0 MJ/m
3
(46.34 MJ/kg); 1.55 SG
GAS�CATEGORIES��
CATEGORY
DESTINATION�COUNTRIES
SUPPLY�PRESSURE�(mbar)
I
2H
AT, CH, CZ, DK, ES, FI, GB, IE, IS, IT, NO, PT, SE
20.0
I
2E
DE, LU
20.0
I
2L
NL
25.0
I
2ER
FR
20.0 / 25.0
I
3P
NL
30.0
I
3P
BE, CH, CZ, ES, FR, GB, GR, IE, LU
37.0
I
3P
BE, CH, DE, CZ, ES, FR, NL
50.0
Input Specifications, GAS Grills, North America:
Input Specifications, GAS Grills, CE Approved Model MWG3W-CE:
Содержание MWE3S
Страница 2: ......