SERVICE MANUAL
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
PART #4526396 (03/30/10)
Page 10
SPECIFICATIONS
SUPPLY�
REQUIRED
TOTAL�
KW�
LOAD
NOMINAL�AMPS�PER�LINE
208V
220V
240V
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT�1
7.65
21.3
21.3
21.3
20.1
20.1
20.1
18.4
18.4
18.4
INPUT�2
15.30
42.6
42.6
42.6
40.2
40.2
40.2
36.8
36.8
36.8
SUPPLY�
REQUIRED
TOTAL�
KW�
LOAD
NOMINAL�AMPS�PER�LINE
208V
240V
L1
L2
L3
L1
L2
L3
INPUT�1
22.95
63.9
63.9
63.9
55.2
55.2
55.2
SUPPLY
TOTAL�kW��
LOAD
LOADING:�(kW/PHASE) NOMINAL�AMPS�PER�LINE
MENNEKES�
PLUG�&�
RECEPTACLE�
MAY�BE�
REQUIRED
230V�/�400V
230V�/�400V
3N~ 400V
50Hz
22.7
L1/L2
L1/L3
L2/L3
L1
L2
L3
7.60
7.60
7.60
33.0
33.0
33.0
Type 748
SUPPLY
TOTAL�kW��
LOAD
LOADING:�(kW/PHASE)
NOMINAL�AMPS�PER�LINE
MENNEKES�
PLUG�&�
RECEPTACLE�
MAY�BE�
REQUIRED
230V�/�400V
230V�/�400V
L1/L2
L1/L3
L2/L3
L1
L2
L3
220V 50Hz
22.7
7.60
7.60
7.60
34.5
34.5
34.5
Type 748
240V 50Hz
22.7
7.60
7.60
7.60
31.6
31.6
31.6
Input Specifications, ELECTRIC FULL SIZE Grills, MWE3W, United States:
Input Specifications, ELECTRIC FULL SIZE Grills, MWE3W, Western Canada:
Input Specifications, Electric Grills, CE Approved Models MWE3W-CE, MWE3S-CE:
Input Specifications, Electric Grills, Export, Non-CE Models MWE3W, MWE3S:
Содержание MWE3S
Страница 2: ......