PART #4521777 (08/18/09)
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
INSTALLATION/OPERATION MANUAL
Page 13
INSTALLATION & STARTUP
(continued)
1. Uncrate unit from crating material
IMPORTANT: RATING PLATE FOR THIS EQUIPMENT IS
LOCATED IN TWO PLACES. ONE IS LOCATED INSIDE BACK
PANEL ON LEFT SIDE, SECOND RATING PLATE LOCATED
UNDER FRONT CONTROL PANEL IN CENTER.
CAUTION: Prior to installation, check the electrical supply
to ensure input voltage and phase match the equipment
voltage rating and phase. See data plate located rear left
side of grill. Back panel removal is required.
NOTE: ENSURE THAT PLATENS ARE STRAPPED DOWN
SECURELY THROUGH STEP 3 TO PREVENT PLATENS
FROM RAISING. SEVERE DAMAGE MAY OCCUR.
2. Tip unit over on its back. Install caster channels and
casters as shown.
3. Carefully rotate grill back on its casters. Now you may
cut and remove the platen securing straps.
4. Remove back body side and Install power cords per
your country / area’s specifi cations.
WARNING: Electrical appliances must be electrically
grounded in accordance with local codes or in the absence
of local codes, with national electric code ANSI/NFPA -
latest version.
All electric connections must be made by a qualifi ed,
properly equipped technician.
MWG3W = 1X NEMA 15-30
MWE3W = 2X NEMA 15-50
MWG3W HAS ONE ELECTRICAL CORD.
MWE3W HAS TWO ELECTRICAL CORDS.
MWE3W
ONLY
Standard Electrical Cord Hookup - UNITED STATES
MWG3W
MWE3W
POWER CORDS
ARE NOT SUPPLIED
BY THE MANUFACTURER
MWG3W = 1X NEMA 15-30
MWE3W = 1X NEMA 15-50
Standard Electrical Cord Hookup - CANADA
MWG3W
MWE3W
POWER CORDS
ARE NOT SUPPLIED
BY THE MANUFACTURER
Ora Red Blk
Wh
Wht
Wht
t Wht Wht
E
E
L1
L1
L1
L1
L1
L1
L1
L1
Ora Red Blk
Wht Wht Wht
1 x 20AMP NEMA 21-20
Hood-Interlock Power Supply; where applicable