PART #4521777 (08/18/09)
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
INSTALLATION/OPERATION MANUAL
Page 11
SPECIFICATIONS
Input Specifi cations, GAS Grills, North America:
ELECTRICAL INPUT
(1) 30-AMP
CIRCUIT &
INTERLOCK
TOTAL
kW
LOAD
LOADING: (kW/PHASE)
NOMINAL AMPS PER LINE
NEMA
RECEPTACLE
REQUIRED
208V / 220V / 240V
208V / 60Hz
220V / 60Hz
240V / 60Hz
L1/L2
L1/L3
L2/L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
10.0
3.25
3.25
3.25
28.0
28.0
28.0
26.3
26.3
26.3
24.0
24.0
24.0
15-30R
INTERLOCK
HVAC Hood / Fire Suppression Interlock Circuit: 7 Amps / 120V / Single Phase
L21-20R
GAS INPUT
GAS
MAX INPUT
(NET) PER
BURNER
(BTU/H)
TOTAL INPUT
RATING
(BTU/H)
INJECTOR
SIZE
AIR SHUTTER
SETTING
(MM)
SUPPLY
PRESSURE
(IN W.C.)
BURNER
MANIFOLD
PRESSURE
(IN W.C.)
NATURAL GAS
32,000
96,000
#35
4.8
3.5
3.5
PROPANE
32,000
96,000
#43
4.8
3.5
10.0
Input Specifi cations, GAS Grills, CE Approved Model MWG3W-CE:
ELECTRICAL INPUT
3N~ 400V
50Hz
TOTAL kW
LOAD
LOADING: (kW/PHASE)
NOMINAL AMPS PER LINE
MENNEKES
PLUG REQUIRED
L1/L2
L1/L3
L2/L3
L1
L2
L3
10.0
3.25
3.25
3.25
14.1
14.1
14.1
Type 748
GAS INPUT
GAS GROUP
MAX INPUT
(NET) PER
BURNER (kW)
TOTAL INPUT
RATING (kW)
INJECTOR
SIZE
AIR SHUTTER
SETTING (mm)
SUPPLY
PRESSURE
(mbar)
BURNER
PRESSURE
(mbar)
VOLUMETRIC
GAS RATE
G20 NG
8.9
26.7
2.79mm (#35)
4.8
20/25
8.7
0.940 m
3
/h
G25 NG
2.79mm (#35)
4.8
20
8.7
G31 LPG
8.9
26.7
2.26mm (#43)
4.8
37/50
8.7
0.69 kg/h
NET HEATING VALUE BY GAS GROUP
G20
G25
G31
34.02 MJ/m
3
; 0.555 SG
29.25 MJ/m
3
; 0.613 SG
88.0 MJ/m
3
(46.34 MJ/kg); 1.55 SG
GAS CATEGORIES
CATEGORY
DESTINATION COUNTRIES
SUPPLY PRESSURE (mbar)
I
2H
AT, CH, CZ, DK, ES, FI, GB, IE, IS, IT, NO, PT, SE
20.0
I
2E
DE, LU
20.0
I
2L
NL
25.0
I
2ER
FR
20.0 / 25.0
I
3P
NL
30.0
I
3P
BE, CH, CZ, ES, FR, GB, GR, IE, LU
37.0
I
3P
BE, CH, DE, CZ, ES, FR, NL
50.0