Installation
RTCSmp
Built-In
Module-Line Dual/Quad Cooktops
28
Part Number 4532415 12/14
4.5.6
Custom-Built Mounting Frame
Mounting Frame for countertop thickness of 1.5mm to 3mm / 16- to 10-gauge (Typ.)
: See section
4.5.4
.
Mounting Frame for countertop thickness of 20-30mm/ 1”
:
For an application with countertop thickness about 1” or 20 – 30 mm, a custom-built mounting frame is
required to flush-mount the glasstop and install the coil carrier sheet properly. When designing an
appropriate frame, use the design criteria and the example below as your guide.
NOTE
: You may re-use existing parts from the mounting frame provided.
NOTE
: Refer to section
4.5.4
and
4.5.5
for cut-out dimensions and recommended installation procedure.
NOTE
: Please contact Garland if you would require assistance on designing a proper frame. CAD files for
the example shown in this section are available upon request.
Mounting Frame Design Criteria
The coil carrier sheet(s) should be easily removable for service/maintenance without taking out the glass-
top.
Height-adjustable feature for leveling the unit during installation is desirable.
Use 10- to 14-gauge metal (typ. 12-gauge) for the mounting frame.
When installing two coil carrier sheets on the same frame, you must install a
non-magnetic steel
partition plate
in between them. This will isolate the magnetic fields and prevent the fields from
interfering each other.
The mounting frame has to support the total weight of the glass, the coil carrier sheet(s), the cookware,
and food product.
Critical dimensions:
o
Countertop cut-out dimension, see section
4.5.4
.
o
Distance from the underside of the coil carrier sheet to the Ceran glass after installation:
50mm
+/- 2mm
.
o
Thickness of glass + silicone silicone seal = 6mm + 3mm + approx. 0.5mm = total
approx. 9.5mm. See section
4.5.5
steps
C to F
.