background image

Function Test 

 

RTCSmp Built-In Module-Line Dual/Quad Cooktops 

 

Part Number 4532415 12/14 

 

Page 37 

5

 

Function Test 

IMPORTANT

 

 

CAUTION

 

When the unit is in use, the cookware will warm up the glass-top.  To 
avoid burn injuries, do not touch the glass-top. 

 

Remove all objects from the glass-top and verify that the glass-top is not cracked or broken. 

CAUTION

 

Do not continue if the glass-top is cracked or broken. Immediately 
switch off the unit and if possible and safe, disconnect it from the 
power outlet. Contact a Factory Authorized Service agency. 

 

Before carrying out the function test, the user must understand how to operate the unit. 

 

Always use a pan suitable for induction cooking, having a bottom diameter of at least 5”(12cm). See 

6.1 

Proper Induction Cookware

 and 

6.2 Proper Placement of Cookware on Dual Hobs

 

NEVER LEAVE AN EMPTY PAN ON AN INDUCTION HOB. 

To perform a function test: 

1.

 

Put some water in the pan and place it in the center of the heating zone. 

2.

 

Turn the control knob to a position between 1 and 12. The LED indicator lamp is bright and the water is 
heated. 

 

ON-Position

Any position where 
“0” is not pointing to 
the LED indicator 
light. The LED is on. 

OFF-Position 

“0” points to the LED 
indicator light. The 
LED is off. 

3.

 

Take the pan away from the hob. Power transmission stops and the indicator lamp starts to blink. 

4.

 

Place the pan back on the heating area. The LED indicator lamp lights up continuously again and the 
heating process resumes. 

5.

 

Turn the control knob to the OFF/“0”-position. The heating process stops; the indicator lamp goes off. 

NOTE

: The green indicator lamp illuminates continuously when energy is being transferred to the pan.  

If the indicator lamp remains off, check: 

 

Is the induction unit connected to the power supply? 

 

Is the control knob in an ON-Position? 

If the indicator lamp keeps blinking and a pan is placed in the heating zone: 

 

Are you using a suitable pan? See chapter 

6.1 Proper Induction Cookware

.

  

 

Is the pan placed in the center of the heating zone? See chapter 

6.2 Proper Placement of Cookware

For further assistance, see chapter 

10 Troubleshooting

 or call a Factory Authorized Service agency. 

Содержание MO DU 7000-360

Страница 1: ...15 12 14 Induction Built In Module Line RTCSmp Dual Quad Cooktops Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for...

Страница 2: ...LLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE Users are cautioned that maintenance...

Страница 3: ...4 Dimensions Control Unit 18 4 4 5 Dimensions Guide Holes Studs 19 4 5 Coil Carrier Sheet Ceran Glass and Mounting Frame 20 4 5 1 Location Ventilation Requirements for Coil Carrier Sheet Installation...

Страница 4: ...Module Line Dual Quad Cooktops 4 Part Number 4532415 12 14 10 Troubleshooting 44 10 1 Common causes for induction unit failure 44 10 2 Problems and Possible Causes 45 10 3 Troubleshooting with Error...

Страница 5: ...ents This appliance component requires additional features and components to comply with appliance and electrical standards It is the responsibility of the customer and installer to interpret and comp...

Страница 6: ...aluminum objects such as aluminum foil on the glass top The induction unit has an internal air cooling system Do not block the air inlet and outlet slots with objects such as containers Any air obstru...

Страница 7: ...ing off the unit there is no heat retained inside the unit NOTE Pan with a bottom diameter smaller than 5 12 cm is not detected by the system 1 7 Cooking Zone Monitoring Each cooking zone is monitored...

Страница 8: ...ion coil power board CPU and the cooking zone in realtime RTCSmp also limits the energy supply during peak load and its special control eliminates interference noises The module line models include a...

Страница 9: ...sheet s and glass top Silicone gaskets not shown included Five Sizes of Frames for 360 or 360FL dual models with 360x360x6mm glasstop for 650 or 650FL dual models with 650x375x6mm glasstop for 720 or...

Страница 10: ...50 MO DU 10000 650 MO DU 7000 720 MO DU 10000 720 DU Dual with FL Full coil at end 7000 14000 360 x 360 650 x 375 720 x 360 MO DU 7000 360FL MO DU 14000 360FL MO DU 14000 650FL MO DU 14000 720FL QU Qu...

Страница 11: ...QUAD Voltage Power Circuits Conductor Size Coils Cook Zones MO QU 14000 650 MO QU 14000 720 208 V AC 3Ph 60Hz 14000W 4x3500 W 22A 2 AWG 10 4 round coils 4 400 V AC 3Ph 50Hz 14000W 4x3500 W 11A 2 1 5m...

Страница 12: ...omer is required Maximum Ambient Temperature In Storage 4 F to 158 F 20 C to 70 C In Operation 41 F to 104 F 5 C to 40 C Maximum Relative Air Humidity In Storage 10 to 90 In Operation 30 to 90 Tempera...

Страница 13: ...ols The installation including electrical installation must be carried out by registered installation contractors only The contractors are responsible for interpreting all instructions correctly and p...

Страница 14: ...ctronic equipment Buildup of hot exhaust air will cause the induction unit to reduce power or to switch off F CLEARANCE Minimum clearance see section 4 2 2 G A Coil Carrier Sheet and Mounting Frame H...

Страница 15: ...ildup of hot exhaust air around the induction unit will cause the unit to reduce power or to switch off Recommended At an appropriate location on the cabinet install an exhaust fan to force hot air ou...

Страница 16: ...le for maintenance and service o the fresh air intake and exhaust air outlet are not blocked 4 3 2 Ventilation Maximum air flow of the fan is 70 63 cfm 120 m3 per hour and therefore a minimum opening...

Страница 17: ...ible for maintenance and service 4 4 2 Ventilation It is possible to install the induction unit near heat producing or steam producing equipment such as an oven or a fryer However use an external fan...

Страница 18: ...ate to install the control unit the operation units power switches and the LED Indicator lights o Keep the Service Interface window on the control unit accessible for service IMPORTANT To prevent the...

Страница 19: ...ver DETAIL A A opening LED field 1 2 opening LED field 1 2 holes for rotary knob fixation field 1 2 holes for rotary knob fixation field 1 2 control unit with or without EMI welding bolts M4 M5 X X Y...

Страница 20: ...remove any hot air away from the induction unit Keep all the combustible materials vapors or liquids away from the coil carrier sheets 4 5 2 Countertop Cut outs Dimensions NOTE The cut out dimensions...

Страница 21: ...allation Refer to sections 4 5 4 1 to 4 5 4 5 for frame and countertop cut out dimensions See section 4 5 5 for installation instructions Mounting Frame for countertop thickness of 20 30mm 1 For an ap...

Страница 22: ...lation RTCSmp Built In Module Line Dual Quad Cooktops 22 Part Number 4532415 12 14 4 5 4 1 Dimensions Mounting Frame for glasstop size 360x360mm 4 5 4 2 Dimensions Mounting Frame for glasstop size 375...

Страница 23: ...ion RTCSmp Built In Module Line Dual Quad Cooktops Part Number 4532415 12 14 Page 23 4 5 4 3 Dimensions Mounting Frame for glasstop size 650x650mm 4 5 4 4 Dimensions Mounting Frame for glasstop size 3...

Страница 24: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops 24 Part Number 4532415 12 14 4 5 4 5 Dimensions Mounting Frame for glasstop size 720x720mm...

Страница 25: ...one adhesive properly to create a water tight seal Before you begin the installation it is very important to use isopropyl alcohol minimum 70 or equivalent to clean the flanges edges and the counter s...

Страница 26: ...stalling multiple glass tops side by side ensure to orient all the logos on the glass tops the same direction ii Align the edges of the glass with the edges of the countertop cut out E Level the glass...

Страница 27: ...oils and temperature sensors installed on the coil carrier sheet must exert a constant pressure of 5mm to the Ceran glass This pressure ensures the temperature monitoring to work properly Do not allow...

Страница 28: ...frame CAD files for the example shown in this section are available upon request Mounting Frame Design Criteria The coil carrier sheet s should be easily removable for service maintenance without tak...

Страница 29: ...ing screws and dropping at the front see F C Support Leveling plates for securing leveling the glass and the coil carrier sheet s D A lip flange for the glass to sit on Retaining rails hook and hinge...

Страница 30: ...ld2 poti LED connection field1 CAN BUS sensor connection field 2 sensor connection field 1 mains connection field 1 2 coil connection Field 1 2 Splitter included 2x 360 x 360 x 6 mm 1x IN MO7000 MODU...

Страница 31: ...ield2 poti LED connection field1 mains connection field 1 2 mains connection field 3 4 CAN BUS CAN BUS coil connection Field 3 4 sensor connection field 4 sensor connection field 3 sensor connection f...

Страница 32: ...glass 1x IN MO14000FL 2x 344 x 355 mm 2 Rectangular Coils Each 3 5 kW 2x MODU 14000 360FL 1x 375 x 650 x 6 mm MODU 14000 650FL MODU 14000 720FL 14000 650FL 14000 720FL Installation 14000 360FL Instal...

Страница 33: ...x 720 x 6 mm 1x Frame for 720x 720mm glass mains field 1 mains field 2 poti LED connection field1 poti LED connection field2 mains field 3 mains field 4 poti LED connection field3 poti LED connection...

Страница 34: ...ection field 3 4 coil connection Field 3 4 field 3 4 Round Coils Full Coils field 2 field 1 ventilation fan cable connection MOQU 24000 720 4x 21000 720 24000 720 Installation 1x IN MO 14000 MOQU 2100...

Страница 35: ...and the line current match the specifications given on the rating plate A stable mains supply must be provided CAUTION Wrong voltage will damage the induction unit Follow strictly the specifications...

Страница 36: ...onents and Cable Connections IMPORTANT Always connect the cables according to the labels affixed next to the connectors and on the cables The cables coils sensors CAN BUS mains must be connected corre...

Страница 37: ...the control knob to a position between 1 and 12 The LED indicator lamp is bright and the water is heated ON Position Any position where 0 is not pointing to the LED indicator light The LED is on OFF P...

Страница 38: ...ore especially when you heat up oil or grease check the cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature cont...

Страница 39: ...hen a hot oversized pan covers the silicone joint underneath the heat from the pan may dry out the silicone overtime and cause this water tight seal to break The induction unit may fail eventually due...

Страница 40: ...energy is being transferred to the cookware ON Position Any position where 0 is not pointing to the LED light The light is on OFF Position 0 points to the LED light The light is off Set and adjust the...

Страница 41: ...t on the hob the heating process is engaged and the indicator light stops flashing and remains bright However the indicator light will keep flashing if the unit is unable to detect any pan or an unsui...

Страница 42: ...commend using an air intake filter in your installation A dirty blocked air intake filter can cause electronic damage to the induction unit Ensure you check and clean the filter at least once a week o...

Страница 43: ...at all times Best Practice Have the induction unit examined once a year by an authorized technician 9 Important Rules Six Simple rules to ensure reliable and repeatable performance of your induction...

Страница 44: ...Inadequate ventilation causing hot air to re enter through the air intake slots Dirty air intake filter Empty pans are left on the cook top while the unit is ON Symptoms When a malfunction occurs the...

Страница 45: ...t temperature The intake air temperature must be lower than 104 F 40 C One phase is missing for units with three phase supply only Check main power supply Defective induction unit Ensure knob is in OF...

Страница 46: ...heck fan operation E04 4 Cook zone temperature too high Failure of sensor unit or sensor unit not connected 1 Check sensor unit Pan empty E05 5 Rotary power switch error Defective potentiometer or bro...

Страница 47: ...d correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information regar...